• 參數(shù)資料
    型號: P3203AB
    英文描述: SIDAC|350V V(BO) MAX|800MA I(S)|TO-220VAR
    中文描述: SIDAC的| 350V五(公報)最大| 800mA的我(縣)|對220VAR
    文件頁數(shù): 6/161頁
    文件大?。?/td> 986K
    代理商: P3203AB
    Table of Contents
    SIDACtor
    Data Book
    ii
    Teccor Electronics
    (972) 580-7777
    Protection Requirements ..............................................................................................................................3-24
    Applicable Regulatory Requirements ...........................................................................................................3-24
    Power Inserter and Line Amplifier Reference Circuit ...................................................................................3-24
    Station Protection Reference Circuit ............................................................................................................3-26
    Primary Protection ................................................................................................................................................3-27
    Overview ......................................................................................................................................................3-27
    Protection Requirements ..............................................................................................................................3-27
    Applicable Regulatory requirements ............................................................................................................3-27
    Primary Protection Reference Circuit ...........................................................................................................3-27
    Secondary Protection ...................................................................................................................................3-29
    Secondary Protectors ...................................................................................................................................3-29
    Protection Requirements ..............................................................................................................................3-29
    Applicable Regulatory Requirements ...........................................................................................................3-29
    Secondary Protection Reference Circuit ......................................................................................................3-29
    Triac Protection ....................................................................................................................................................3-31
    Thyristors .....................................................................................................................................................3-31
    Thyristor Reference Circuit ..........................................................................................................................3-31
    Data Line Protectors ............................................................................................................................................3-32
    Data Line Protection .....................................................................................................................................3-32
    Protection Requirements ..............................................................................................................................3-32
    Data Line Reference Circuit .........................................................................................................................3-32
    Notes ....................................................................................................................................................................3-33
    Regulatory Requirements
    4-1
    GR 1089-Core ........................................................................................................................................................4-3
    Overview ........................................................................................................................................................4-3
    Requirements .................................................................................................................................................4-3
    Passing Criteria ..............................................................................................................................................4-5
    Lightning Fault Immunity Test ........................................................................................................................4-5
    First Level Lightning Surge Test ....................................................................................................................4-5
    Second Level Lightning Surge Test ...............................................................................................................4-6
    AC Power Fault Tests ....................................................................................................................................4-6
    First Level AC Power Fault Criteria ................................................................................................................4-7
    Second Level AC Power Fault Criteria ...........................................................................................................4-7
    Second Level AC Power Fault Criteria for Non-Customer Premises Equipment ...........................................4-7
    Second Level AC Power Fault for Customer Premises Equipment ...............................................................4-8
    Current Limiting Protector Test ......................................................................................................................4-9
    Short Circuit Test ...........................................................................................................................................4-9
    Intra-Building Lightning and AC Power Fault Test .......................................................................................4-10
    ITU-T K.20 and K.21 ............................................................................................................................................4-11
    Overview ......................................................................................................................................................4-11
    ITU-T K.20 ....................................................................................................................................................4-11
    ITU-T K.21 ....................................................................................................................................................4-11
    External Protectors .......................................................................................................................................4-12
    Equipment Boundaries .................................................................................................................................4-12
    Permitted Malfunction or Damage ................................................................................................................4-12
    FCC PART 68 ......................................................................................................................................................4-19
    Overview ......................................................................................................................................................4-19
    Over-Voltage Test ........................................................................................................................................4-19
    Metallic Voltage Surge .................................................................................................................................4-19
    Longitudinal Voltage Surge ..........................................................................................................................4-19
    相關PDF資料
    PDF描述
    P3203ABRP SIDAC|350V V(BO) MAX|800MA I(S)|TO-220VAR
    P3203AC SIDAC|350V V(BO) MAX|800MA I(S)|TO-220VAR
    P6002AB SIDAC|350V V(BO) MAX|800MA I(S)|TO-220VAR
    P6002ABRP SIDAC|350V V(BO) MAX|800MA I(S)|TO-220VAR
    P6002AC SIDAC|350V V(BO) MAX|800MA I(S)|TO-220VAR
    相關代理商/技術參數(shù)
    參數(shù)描述
    P3203AB60 功能描述:硅對稱二端開關元件 3Chp 270V 100A RoHS:否 制造商:Bourns 轉折電流 VBO:40 V 最大轉折電流 IBO:800 mA 不重復通態(tài)電流: 額定重復關閉狀態(tài)電壓 VDRM:25 V 關閉狀態(tài)漏泄電流(在 VDRM IDRM 下): 保持電流(Ih 最大值):50 mA 開啟狀態(tài)電壓:5 V 關閉狀態(tài)電容 CO:120 pF 最大工作溫度:+ 150 C 安裝風格:SMD/SMT 封裝 / 箱體:DO-214AA
    P3203AB60TP 功能描述:硅對稱二端開關元件 3Chp 270V 100A RoHS:否 制造商:Bourns 轉折電流 VBO:40 V 最大轉折電流 IBO:800 mA 不重復通態(tài)電流: 額定重復關閉狀態(tài)電壓 VDRM:25 V 關閉狀態(tài)漏泄電流(在 VDRM IDRM 下): 保持電流(Ih 最大值):50 mA 開啟狀態(tài)電壓:5 V 關閉狀態(tài)電容 CO:120 pF 最大工作溫度:+ 150 C 安裝風格:SMD/SMT 封裝 / 箱體:DO-214AA
    P3203ABL 功能描述:硅對稱二端開關元件 3Chp 270V 100A RoHS:否 制造商:Bourns 轉折電流 VBO:40 V 最大轉折電流 IBO:800 mA 不重復通態(tài)電流: 額定重復關閉狀態(tài)電壓 VDRM:25 V 關閉狀態(tài)漏泄電流(在 VDRM IDRM 下): 保持電流(Ih 最大值):50 mA 開啟狀態(tài)電壓:5 V 關閉狀態(tài)電容 CO:120 pF 最大工作溫度:+ 150 C 安裝風格:SMD/SMT 封裝 / 箱體:DO-214AA
    P3203ABL60 功能描述:硅對稱二端開關元件 3Chp 270V 100A RoHS:否 制造商:Bourns 轉折電流 VBO:40 V 最大轉折電流 IBO:800 mA 不重復通態(tài)電流: 額定重復關閉狀態(tài)電壓 VDRM:25 V 關閉狀態(tài)漏泄電流(在 VDRM IDRM 下): 保持電流(Ih 最大值):50 mA 開啟狀態(tài)電壓:5 V 關閉狀態(tài)電容 CO:120 pF 最大工作溫度:+ 150 C 安裝風格:SMD/SMT 封裝 / 箱體:DO-214AA
    P3203ABLRP 功能描述:硅對稱二端開關元件 3Chp 270V 100A RoHS:否 制造商:Bourns 轉折電流 VBO:40 V 最大轉折電流 IBO:800 mA 不重復通態(tài)電流: 額定重復關閉狀態(tài)電壓 VDRM:25 V 關閉狀態(tài)漏泄電流(在 VDRM IDRM 下): 保持電流(Ih 最大值):50 mA 開啟狀態(tài)電壓:5 V 關閉狀態(tài)電容 CO:120 pF 最大工作溫度:+ 150 C 安裝風格:SMD/SMT 封裝 / 箱體:DO-214AA