THE PULSE OF THE FUTURE
Directed Energy, Inc.
An
IXYS
Company
2401 Research Blvd., Suite 108
Fort Collins, CO USA 80526
970-493-1901 Fax: 970-493-1903
Email: deiinfo@directedenergy.com
Web: http://www.directedenergy.com
9200-0220 R
EV
3
S
PECIFICATIONS
S
UBJECT
T
O
C
HANGE
W
ITHOUT
N
OTICE
(1)
The current adjustment range is 0A to 150A, however the pulse performance is not
characterized at output current less than 10A. Pulse fidelity (i.e. overshoot or ripple)
may exceed specifications at current levels less than 10A.
SPECIFICATIONS
PARAMETER
PULSE OUTPUT CURRENT
Current Amplitude Range
Voltage Polarity
Maximum Output Voltage
Output Current Resolution
Accuracy At
≥
25A Setpoint
Display Resolution
Value
0A to 150A
(1)
Floating
40V
0.5A
1%
0.5A When the laser is off, the displayed value is the amplitude setpoint;
when the laser is on, both the setpoint and the actual measured current are
displayed.
<
25
μ
s (10%-90%)
<
25
μ
s (10%-90%)
50
μ
s to 20ms
Single Shot to 5KHz
50% Maximum, 20% @ 150A, 40V output
Maximum average output power is 1200W. Maximum duty cycle is depend-
ent upon output voltage and current, but cannot exceed 1200W average
output power or 75A average output current
<3%
<25
μ
s (90% to 1% of final value)
<1.5%
Pulse Rise Time
Pulse Fall Time
Pulse Width
Pulse Recurrence Frequency Range
Maximum Duty Cycle and Average Power
Over/undershoot
Settling Time
Output Ripple
Jitter
Output Connector
CURRENT LIMIT
<500ns shot-to-shot
High Current DSUB, Rear Panel
Range
Resolution
TRIGGER IN
Type
Trigger Input
Minimum Trigger Pulse Width
Input Trigger Connector
SYNC MONITOR OUTPUT
Sync Monitor
Sync Monitor Connector
CURRENT MONITOR OUTPUT
CVR Monitor
CVR Monitor Connector
VOLTAGE MONITOR OUTPUT
Voltage Monitor
Voltage Monitor Connector
GENERAL
Operating Temperature Range
Cooling Requirements
Input AC Power
Dimensions (H X W X D)
10A to 165A
1A
Positive Edge Trigger
TTL or +5V ±1V, into 50
100ns
BNC, Front Panel
TTL output into 50
BNC, Front Panel
50A/1V into 1 Meg
,
typically within 1% of the displayed actual current
BNC, Front Panel
10V/1V into 1 Meg
,
typically within 1% of the actual voltage
BNC, Front Panel
0
°
C to +40
°
C
Air cooled
90-260VAC, 50-60Hz