PT-6503
65W Triple Output with 3.3V output
300 Myles standish Blvd., Taunton, MA 02780
ph: 1-800-823-8082 Fax: 508-823-8181
WWW.AsTRODYNE.COM
120~160%
ratedoutputpower
SPECIFICATION
CH1
CH2
CH3
MODEL
DCVOLTAGE
RATEDCURRENT
CURRENTRANGE
OUTPUT
LINEREGULATION
LOADREGULATION
SETUP,RISETIME
HOLDTIME (Typ.)
VOLTAGERANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
INPUT
INRUSHCURRENT (Typ.)
LEAKAGECURRENT
SAFETY STANDARDS
WORKINGTEMP.
WORKINGHUMIDITY
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
OVERLOAD
OVERVOLTAGE
ACCURRENT (Typ.)
3.3V
6A
0~7A
50mVp-p
CH1:3~3.6V
+4,-2%
8.0%
8.0%
1.0%
3.0%
3.0%
1.0%
2.0%
3.0%
800ms,50msatfullload
60msatfullload
90~264VAC127~370VDC
47~63Hz
72%
1.8A/115VAC0.9A/230VAC
COLDSTART 20A/115V40A/230V
<1mA/240VAC
5.75~6.75Von+5V
Protectiontype: Hiccupmode,recoversautomaticallyafterfaultconditionisremoved
Protectiontype: Hiccupmode,recoversautomaticallyafterfaultconditionisremoved
UL60950-1, TUVEN60950-1 Approved
-10~+60
(Refertooutputloadderatingcurve)
20~90%RHnon-condensing
-20~+85
,10~95%RH
0.03%/
10~500Hz,2G10min./1cycle,Periodfor60min.eachalongX, Y,Zaxes
(0~50
)
222Khrsmin.MIL-HDBK-217F(25
)
127*76.2*42mm(L*W*H)
0.28Kg;54pcs/16.2Kg/1.35CUFT
6A
1A
0.2~10A
0~1.2A
50mVp-p
100mVp-p
5V
12V
HARMONICCURRENT
EMSIMMUNITY
CompliancetoEN55022(CISPR22)ClassB
Complianceto EN61000-3-2,-3
CompliancetoEN61000-4-2,3,4,5,6,11Lightindustrylevel,criteriaA
VOLTAGEADJ.RANGE
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
I/P-O/P:3KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC1min.
I/P-O/P,I/P-FG,O/P-FG:100MOhms/500VDC
RIPPLE&NOISE(max.)
Note.2
VOLTAGETOLERANCE
Note.3
EMICONDUCTION&RADIATION
ENVIRONMENT
SAFETY &
EMC
(Note4)
PROTECTION
Totalpowermax.61.8W(CH1+CH2max.54W)
RATEDPOWER
PT-6503
OUTPUTNUMBER