Philips Semiconductors
Preliminary specification
PDIUSBP11
Universal Serial Bus transceiver
1997 Sep 16
3
RECOMMENDED OPERATING CONDITIONS
SYMBOL
PARAMETER
CONDITIONS
LIMITS
UNIT
MIN.
MAX.
V
CC
DC supply voltage
3.0
3.6
V
V
I
DC Input voltage range
0
5.5
V
V
I/O
DC input range for I/O’s
0
V
CC
V
V
O
DC output voltage range
0
V
CC
V
T
amb
Operating ambient temperature range in
free air
See DC and AC characteristics
for individual device
0
+70
°
C
ABSOLUTE MAXIMUM RATINGS
1, 2
In accordance with the Absolute Maximum Rating System (IEC 134) Voltages are referenced to GND (ground = 0V)
SYMBOL
PARAMETER
CONDITIONS
LIMITS
UNIT
MIN
MAX
V
CC
DC supply voltage
–0.5
+6.5
V
I
IK
DC input diode current
V
I
< 0
–
–50
mA
V
I
DC input voltage
Note 3
–0.5
+5.5
V
V
I/O
DC input voltage range for I/O’s
–0.5
V
CC
+0.5
V
I
OK
DC output diode current
V
O
> V
CC
or V
O
< 0
–
50
mA
V
O
DC output voltage
Note 3
–0.5
V
CC
+0.5
V
I
O
DC output source or sink current for VP/VM,
RCV pins
V
O
= 0 to V
CC
–
15
mA
I
O
DC output source or sink current for D+/D–
pins
V
O
= 0 to V
CC
–
50
mA
I
GND
, I
CC
DC V
CC
or GND current
–
100
mA
T
stg
Storage temperature range
–60
+150
°
C
P
tot
Power dissipation per package
mW
NOTES:
1. Stresses beyond those listed may cause permanent damage to the device. These are stress ratings only and functional operation of the
device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to
absolute-maximum-rated conditions for extended periods may affect device reliability.
2. The performance capability of a high-performance integrated circuit in conjunction with its thermal environment can create junction
temperatures which are detrimental to reliability. The maximum junction temperature of this integrated circuit should not exceed 150
°
C.
3. The input and output voltage ratings may be exceeded if the input and output clamp current ratings are observed.