Electrical Specification for 2.50V +
_5% over the specified temperature range and
the frequency range of 40 to 325 MHz
Item
Min
Max
Unit
Condition
Frequency Accuracy
“45"
-50
+50
ppm
For all supply voltages, load changes, aging for 1
year, shock, vibration and temperatures
“44"
-25
+25
“20"
-20
+20
Output Waveform
PECL /ECL
Output High Level (0
oC to 85oC)
1.475
1.760
volts
Referenced to Ground, V
CC = 2.5 V
0.975
1.260
volts
Referenced to termination voltage, V
CC = 2.5 V
-1.025 -0.740
volts
Referenced to Vcc, V
CC = 2.5 V
Output High Level (-40
oC)
1.415
1.620
volts
Referenced to Ground, V
CC = 2.5 V
0.915
1.12
volts
Referenced to termination voltage, V
CC = 2.5 V
-1.085
-0.88
volts
Referenced to Vcc, V
CC = 2.5 V
Output Low Level (0
oC to 85oC)
0.690
1.095
volts
Referenced to Ground, V
CC = 2.5 V
0.190
0.595
volts
Referenced to termination voltage, V
CC = 2.5 V
-1.810 -1.405
volts
Referenced to Vcc, V
CC = 2.5 V
Output Low Level (-40
oC)
0.670
1.195
volts
Referenced to Ground, V
CC = 2.5 V
0.170
0.695
volts
Referenced to termination voltage, V
CC = 2.5 V
-1.830 -1.305
volts
Referenced to Vcc, V
CC = 2.5 V
Output Symmetry
45
55
%
at 50% point of V
CC
(See load circuit)
Jitter
-
0.6
pS RMS
12 KHz to 20 MHz from the output frequency
-
2.8
pS RMS
10 Hz to 1 MHz from the output frequency
Output T
RISE and TFALL
-
0.7
nS
Vth is 20% and 80% of waveform
V
CC Supply Current (ICC)-
90
mA
Enable/Disable Internal Pull-up
50
-
Kohm
to V
CC, measured with Pad 1 = 0.0 volts
V disable
-
0.6
volts
Referenced to pad 3
V enable
1.7
-
volts
Referenced to pad 3
Output leakage
V
OUT = VCC
-10
+10
uA
Pad 1 low, device disabled
V
OUT = 0V
-10
+10
uA
Enable time
100
500
nS
Time for output to reach a logic state, the output
frequency is correct at the specified Start Time.
Disable time
-
200
nS
Time for output to reach a high Z state
Start up time
-
10
mS
Time for output to reach specified frequency
Operating Temperature Range
-10
+70
oC
Standard Temperature Range
- 20
+70
oC
Extended Temperature Range
“C” Option
- 40
+85
oC
Extended Temperature Range
“E” Option
Storage Temperature Range
-55
+125
oC
Standby Current I
CC
-
30
uA
Pad 1 low, device disabled
Specifications with Pad 1 E/D open circuit unless stated otherwise