2
EN/LZT 146 30 R2A Ericsson Microelectronics AB, October 2000
NOTES:
1)
The input voltage range 38…72 V dc meets
the European Telecom Standard prETS
300 132-2 Nominal input voltage range in
48 V and 60 V dc power systems,
– 40.5… –57.0 V and –50.0… – 72.0 V
respectively. At input voltages exceeding 72 V
(abnormal voltage) the power loss will be
higher than at normal input voltage and TC
must be limited to max +95 °C. Absolute max
continuous input voltage is 75 V dc. Output
characteristics will be marginally affected at
input voltages exceeding 72 V.
2)
The power modules will operate down to
36 V, when VI decreases, but will turn on at
VI 38 V, when VI increases (see also Operating
information).
3)
The test is applicable for through-hole versions.
Stress in excess of Absolute Maximum
Ratings may cause permanent damage.
Absolute Maximum Ratings, sometimes
referred to as no destruction limits, are
normally tested with one parameter at a
time exceeding the limits of Output data
or Electrical Characteristics. If exposed to
stress above these limits, function and per-
formance may degrade in an unspecified
manner.
General
Absolute Maximum Ratings
Characteristics
Isolation voltage
(input to output test voltage)
VISO
min
max
Unit
TC
Case temperature at full output power
–45
+100
°C
TS
Storage temperature
–55
+125
°C
VI
Continuous input voltage1)
–0.5
+75
V dc
1,500
V dc
Vtr
Transient input energy
0.01
Ws
VRC
Remote control voltage pin 10, 11 ref. to pin 17
–5
+16
V dc
Vadj
Output adjust voltage pin 8, 9 ref. to pin 17
–5
+40
V dc
Environmental Characteristics
Characteristics
Frequency
10…500 Hz
Amplitude
0.75 mm
Acceleration
10 g
Number of cycles
10 in each axis
Vibration
(Sinusoidal)
JESD 22-B103
(IEC 68-2-6 Fc)
Test procedure & conditions
Frequency
10…500 Hz
Acceleration density
spectrum
0.5 g2/Hz
Duration
10 min in 3 directions
Reproducability
medium (IEC 62-2-36)
MIL-STD-883
Method 2026
(IEC 68-2-34 Ed)
Random
vibration
Peak acceleration
200 g
Shock duration
3 ms
Shock
(Half sinus)
JESD 22-B104
(IEC 68-2-27 Ea)
Temperature
85°C
Humidity
85% RH
Duration
1000 hours
Temperature
–40°C…+125°C
Number of cycles
500
Temperature, solder
260°C
Duration
10…13 s
Temperature
change
Accelerated
damp heat
Solder
resistability3)
JESD 22-A104
(IEC 68-2-14 Na)
JESD 22-A101
(IEC 68-2-3 Ca
with bias)
JESD 22-B106
(IEC 68-2-20 Tb 1A)
Duration
96 h
Temperature
35°C
Concentration
5 %
IEC 68-2-11 Ka
Aggressive
environment
Input TC <TCmax unless otherwise specified
mW
Input stand-by power
PRC
VI
Input voltage range1)2)
38
72
V
VIoff
Turn-off input voltage
30.0
36.0
V
34.5
See typical characteristics
VIon
Turn-on input voltage
38.0
V
36
See typical characteristics
CI
Input capacitance
mF
1.4
PIi
Input idling power
IO= 0, TC = –30…+ 95 °C
(VI= 53V)
(VI= 66V)
310
(VI= 53V)
(VI= 66V)
30
45
TC = –30…+ 95 °C,
RC connected to pin 17
Characteristics
Conditions
min
typ
max
Unit