PRODUCT SPECIFICATION
4 (6)
Prepared (also subject responsible if other)
No.
ECOCOLO
2/1301-BMR 629 8210 Uen
Approved
Checked
Date
Rev
Reference
EJANLLI
2009-08-31
B
5V, 40A / 200W Electrical Specification
PMR 8210
TP1 = -40 to +85C, VI = 8 to 14 V, RSET = 1.37 k, unless otherwise specified under Conditions.
Typical values given at: Tref = +25°C, VI= 12 V, max IO, unless otherwise specified under Conditions.
Additional Cin = 1000+22 F and Cout = 1000 F. See Operating Information section for selection of capacitor types.
Connect the sense pin, where available, to the output pin.
Characteristics
Conditions
min
typ
max
Unit
VI
Input voltage range
8
14
V
VIoff
Turn-off input voltage
Decreasing input voltage
6.7
V
VIon
Turn-on input voltage
Increasing input voltage
7.2
8.0
V
CI
Internal input capacitance
44
μ
F
PO
Output power
0
200
W
50 % of max IO
95.6
η
Efficiency
max IO
95.5
%
Pd
Power Dissipation
max IO
9.5
11.5
W
Pli
Input idling power
IO= 0 A, VI = 12 V
2.4
W
PRC
Input standby power
VI = 12 V (turned off with RC)
0.2
W
IS
Static Input current
VI = 12 V, max IO
17.4
A
fs
Switching frequency
0-100 % of max IO, see Note 1
600
kHz
VOi
Output voltage initial setting and
accuracy
TP1 = +25°C, VI = 12 V, max IO
4.950
5.0
5.050
V
Output voltage tolerance band
0-100 % of max IO
4.85
5.15
V
Idling voltage
IO = 0 A
4.998
5.008
V
Line regulation
max IO
5
10
mV
VO
Load regulation
VI = 12 V, 0-100 % of max IO
5
10
mV
Vtr
Load transient
voltage deviation
±135
mV
ttr
Load transient recovery time
VI = 12 V, Load step 50-100-50 % of
max IO, di/dt = 2.5 A/μs Without
TruboTrans, Cout = 1000 F, Type C
200
μ
s
Vtr
Load transient
voltage deviation
±35
mV
ttr
Load transient recovery time
VI = 12 V, Load step 50-100-50 % of
max IO, di/dt = 2.5 A/μs
With TruboTrans, Cout = 5000 F,
Type C, RTT=SHORT
400
μ
s
ts
Start-up time
(from VI connection to 90 % of VOi)
13.1
ms
max IO
630
μ
s
tf
VI shut-down fall time.
(From VI off to 10 % of VO)
IO =0.4A
51.8
ms
RC start-up time
max IO
12.6
ms
max IO
425
μ
s
{tRC tInh} RC shut-down fall time
(From RC off to 10 % of VO)
Io = 0.4 A
35.2
ms
IO
Output current
0
40
A
Ilim
Current limit threshold
TP1 < max TP1
80
A
Isc
Short circuit current
TP1 = 25C, {see Note 3}
90
A
Cout
Recommended Capacitive Load
TP1 = 25C, {see Note 4}
1000
10000
F
VOac
Output ripple & noise
See ripple & noise section,
max IO
20
mVp-p
Note 1: Frequency may be adjusted with SmartSync pin. See Operating Information section
Note 2: See Operating Information section for TurboTrans technology
Note 3: Describe short circuit current characteristic, i.e. fold-back, hiccup or RMS, in one short sentence or type only “See Operating Information section.”)
Note 4: 1000 F of external non-ceramic output capacitance is required for basic operation. Adding additional capacitance at the load further improves transient response. Up to 1000 F of
ceramic capacitance may be added in addition to the required non-ceramic capacitance. When not using TurboTrans technology, 8000 F capacitance is allowed; When using TurboTrans
technology, up to 10000 F capacitance is allowed. For more information, see Operating Information Section.
E
PMR 8000 series
PoL Regulator
Input 8 - 14 V, Output up to 40 A / 210 W
EN/LZT 146 411 R1B November 2009
Ericsson AB
Technical Specication
7