T
Technical
echnical
S
Specification
pecification
PQ60010QP
PQ60010QPA60
A60
Product # PQ60010QPA60
Phone 1-888-567-9596
Doc.# 005-2QP610F Rev. D
9/21/07
Page 1
TThhee PPQ
Q6
60
00
01
10
0Q
QPPA
A6
60
0 PPoow
weerrQ
Qoorr PPeettaa qquuaarrtteerr--bbrriicckk ccoonnvveerrtteerr
iiss aa nneexxtt--ggeenneerraattiioonn,, bbooaarrdd--m
moouunnttaabbllee,, iissoollaatteedd,, ffiixxeedd ssw
wiittcchh--
iinngg ffrreeqquueennccyy D
DC
C/
/D
DC
C ccoonnvveerrtteerr tthhaatt uusseess ssyynncchhrroonnoouuss rreeccttiiffii--
ccaattiioonn ttoo aacchhiieevvee eexxttrreem
meellyy hhiigghh ccoonnvveerrssiioonn eeffffiicciieennccyy.. TThhee
ppoow
weerr ddiissssiippaatteedd bbyy tthhee ccoonnvveerrtteerr iiss ssoo lloow
w tthhaatt aa hheeaattssiinnkk iiss
nnoott rreeqquuiirreedd,, w
whhiicchh ssaavveess ccoosstt,, w
weeiigghhtt,, hheeiigghhtt,, aanndd aapppplliiccaa--
ttiioonn eeffffoorrtt.. A
Allll ooff tthhee ppoow
weerr aanndd ccoonnttrrooll ccoom
mppoonneennttss aarree
m
moouunntteedd ttoo tthhee m
muullttii--llaayyeerr PPC
CBB ssuubbssttrraattee w
wiitthh hhiigghh--yyiieelldd ssuurrffaaccee
m
moouunntt tteecchhnnoollooggyy.. SSiinnccee tthhee PPoow
weerrQ
Qoorr ccoonnvveerrtteerr hhaass nnoo
eexxpplliicciitt tthheerrm
maall iinntteerrffaacceess,, iitt iiss eexxttrreem
meellyy rreelliiaabbllee.. TThhee PPeettaa
sseerriieess ooffffeerrss iinndduussttrryy lleeaaddiinngg oouuttppuutt ccuurrrreennttss ffoorr aannyy ssttaannddaarrdd
qquuaarrtteerr--bbrriicckk m
moodduullee.. RRooH
HSS ccoom
mpplliiaanntt ((sseeee ppaaggee
1PQ60010QPA60 Module
48V
48V in
in
1.0V
1.0Vout
out
60Amp
2000Vdc
Quar
Quar ter-brick
ter-brick
Input
Output
Current
Isolation
DC/DC Conver
DC/DC Conver ter
ter
Ultra-high efficiency, 86% half load, 83% full load
Delivers up to 60 amps of output current with minimal
derating - no heatsink required
Wide input voltage range: 36V – 75V, with 100V
100ms input voltage transient capability
Fixed frequency switching provides predictable EMI
performance
No minimum load requirement means no preload
resistors required
Operational Features
Input under-voltage lockout disables converter at low
input voltage conditions
Output current limit and short circuit protection protects
converter and load from permanent damage and conse-
quent hazardous conditions
Active back bias limit prevents damage to converter
from external load induced pre-bias
Output over-voltage protection protects load from dam-
aging voltages
Thermal shutdown protects converter from abnormal
environmental conditions
Pr
Protection Features
otection Features
2000V, 30 MW input-to-output isolation provides
input/output ground separation
UL/cUL 60950-1 recognized (US & Canada), basic
insulation rating
TUV certified to EN60950-1
Meets 72/23/EEC and 93/68/EEC directives which
facilitates CE Marking in user’s end product
Board and plastic components meet UL94V-0 flamma-
bility requirements
Safety Features
Industry standard quarter-brick pin-out configuration
Industry standard size: 1.45” x 2.3” (36.8x58.4mm)
Total height less than 0.45” (11.4mm), permits better
airflow and smaller card pitch
Total weight: 1.5 oz. (42 grams)
Flanged pins designed to permit surface mount solder-
ing (avoid wave solder) using FPiP technique
Mechanical Features
On/Off control referenced to input side (positive and
negative logic options are available)
Remote sense for the output voltage compensates for
output distribution drops
Output voltage trim permits custom voltages and volt-
age margining
Contr
Control Features
ol Features