el 01978 262255
Fax: 01978 262233
ellison sensors international
Sensor House, Wrexham Technology Park, Wrexham, LL 13 7YP, Wales, U.K.
PRTRAN
SPECIFICATION
DIMENSIONS / WIRING DETAILS
ORDERING INFORMATION
STATE MODEL NUMBER AND PRESSURE RANGE REQUIRED:-
ie: PR3200 0-10mbarDP
PR3200 DIFFERENTIAL PRESSURE TRANSMITTER
D.P. PRESSURE RANGES
0 - 250 mbar
0 - 500 mbar
0 - 750 mbar
0 - 1 bar
0 - 2 bar
0 - 4 bar
0 - 10 bar
0 - 20 bar
0 - 40 bar
0 - 100 bar
0 - 200 bar
TRANSMITTER WIRING DIAGRAM
LOAD DRIVING CHART
MODEL NO.
DESCRIPTION
PR3200
DP Transmitter 0-250mbar to
0-200 bar
PR3200/MP
Mounting Angle Plate
Reverse polarity.......................Protected
Load driving capability..............1150
@ 36Vdc
Output short circuit (to ground)No damage
Insulation resistance................ 100M
@ 100Vdc elec conn to case
Response time (63%).............. 1.5mS
Adjustment............................... ±10%FSO Zero and Span
ENVIRONMENTAL
Pressure media....................... Compatible with alumina +304 S.S
Operating temperature range.. -20 to +85 °C
Storage temperature range......-40 to +90°C
Thermal effect Zero................. <±0.03% FSO/°C
Thermal sensistivity................. <±0.03% FSO/°C
Vibration tolerance................... 10g’s to 50Hz
Mechanical shock tolerance.... 15g@s (11mS)
Operating humidity................... 95% RH
PHYSICAL
Pressure connections.............." BSP female x 2
Electrical connection................ DIN plug + socket to DIN43650
Mounting...................................Via mounting plate (optional extra)
Enclosure rating....................... IP65
Natural frequency.................... 10 Khz (min)
Weight...................................... 780 grams
Materials...................................300 series stain’stl body/
connector alumina diaphragm
INPUT
Pressure ranges...................................0-250 mbarDP
to 0-200 barDP
Pressure reference...............................Differential
Operation mode.....................................Uni or Bi-directional
Static pressure max..............................4 x range (max)
Common mode pressure......................4 x range (max)
OUTPUT
Span......................................................4-20 mA
Type......................................................2 wire
ACCURACY
Zero offset.............................................<±1% FSO
Span tolerance......................................<±1% FSO
Combined non-linearity / hysteresis .... <±0.3% FSO
Repeatability..........................................<±0.1% FSO
Long term stability.................................<±0.2% FSO / 6 months
Common mode pressure error ............<±2% / 4 x DP range
ELECTRICAL
Supply voltage.......................................13-36Vdc
Supply voltage effects...........................3μA/V