Industrial Environment
Switching Regulators 19"
PSL-Family
Edition 2/96 - Melcher AG
5 - 39
MELCHER
The Power Partners.
5.2
Standards and Approvals
All Melcher power supplies are subject to manufacturing
surveillance in accordance with ISO 9001 standards.
All units are UL recognized as per UL 1950, UL 1012 and
CAN/CSA C22.2 No. 234-M90.
Installation Instructions
The connector pin allocation table defines the electrical
potentials and the physical pin position on the connector.
Pin no. 32 is the protective ground pin and is protruding, i.e.
attaching the female connector, this pin provides electrical
contact first. The modules should only be wired via the fe-
male connector H11 (according to DIN 41612) to ensure
requested safety!
Protection Degree
The protection degree is defined by IP 30 (equipped with
any potentiometer adjustable option: IP 20). The protection
degree applies only if the module is plugged-in or the fe-
male connector is properly attached to the module.
Table 5: Temperature specifications
Temperature
Standard -7
Option -9
Characteristics
Conditions
min
max
min
max
Unit
TA
Ambient temperature
Ui min...U i max
–25
71
–40
71
°C
TC
Case temperature
Io = 0...Io nom
–25
95
–40
95
TS
Storage temperature
Not operational
–40
100
–55
100
Immunity to Environmental Conditions
Table 4: Mechanical stress
Test Method
Standard
Test Conditions
Status
Ca
Damp heat
DIN 40046 part
Temperature:
40 ±2
°C
Unit not
steady state
IEC 68-2-3
Relative humidity:
93 +2/-3 %
operating
MIL-STD-810D section 507.2
Duration:
56 days
Ea
Shock
DIN 40046 part 7
Acceleration amplitude:
100 gn = 981 m/s2
Unit
(half-sinusoidal)
IEC 68-2-27
Bump duration:
6 ms
operating
MIL-STD-810D section 516.3
Number of bumps:
18 (3 each direction)
Eb
Continuous shock
DIN 40046 part 26
Acceleration amplitude:
40 gn = 392 m/s2
Unit
(half-sinusoidal)
IEC 68-2-29
Bump duration:
6 ms
operating
MIL-STD-810D section 516.3
Number of bumps:
6000 (1000 each direction)
Fc
Vibration
DIN 40046 part 8
Frequency (1 Oct/min):
10...2000 Hz
Unit
(sinusoidal)
IEC 68-2-6
Max. vibration amplitude:
0.35 mm (10...60 Hz)
operating
MIL-STD-810D section 514.3
Acceleration amplitude:
5 gn = 49 m/s2 (60...2000 Hz)
Test duration:
7.5 h (2.5 h each axis)
Fda
Random vibration
DIN 40046 part 23
Acceleration spectral density: 0.05 g2/Hz
Unit not
wide band
IEC 68-2-35
Frequency band:
20...500 Hz
operating
reproducibility high
Acceleration magnitude:
4.9 grms
Test duration:
3 h (1 h each axis)
Kb
Salt mist
DIN 40046 part 105
Concentration:
5% (30
°C)
Unit not
cyclic
IEC 68-2-52
Duration:
2 h per cycle
operating
(sodium chloride
Storage:
40
°C, 93 % rel. humidity
NaCl solution)
Storage duration:
22 h per cycle
Number of cycles:
3
Table 3: H11 connector pin allocation and designation
Electrical Determination
Type H11
Pin No.
Design.
R-input (or inhibit input) 1
2
R (i)
Undervoltage monitor (Option D)
5
D
Output voltage (negative)
8
Go–
Output voltage (negative)
11
Go–
Output voltage(positive)
14
Vo+
Output voltage (positive)
17
Vo+
Input voltage (negative)
20
Gi–
Input voltage (negative)
23
Gi–
Input voltage (positive)
26
Vi+
Input voltage (positive)
29
Vi+
Protective ground (protruding pin)
32
1 R-input (output voltage programming) not available with
option P (potentiometer) or option i (inhibit)
2
5
8
11
14
17
20
23
26
29
32
Fig. 2