![](http://datasheet.mmic.net.cn/260000/PT500-M1ABCHPHN_datasheet_15958506/PT500-M1ABCHPHN_2.png)
PT500 4/99 REV A
Page
2
Input Specifications
Parameters
Operating Range
Input Current
Inrush Current
Conditions
47-63Hz
Nominal line, full load
120V
AC
, 25
0
C, cold start
240V
AC
, 25
0
C, cold start
Nominal line, full load
Full load
Full load
Min
90
Typ
Max
264
8
30
70
Units
V
AC
A
A
pk
A
pk
%
m
sec
Efficiency
Holdup
Power Factor
(1)
70
20
0.99
Notes: (1) Harmonic currents meet EN61000-3-2
Output Voltages and Maximum Rated Loads
OUTPUT #1
MODEL NUMBER
V
OUT
PT500-U1A
± 3.3V
PT500-U2A
± 3.3V
PT500-U2B
± 3.3V
PT500-U3A
±3.3V
PT500-U3B
±3.3V
PT500-U4C
±3.3V
PT500-U4D
±3.3V
PT500-U4E
±3.3V
PT500-U4F
±3.3V
PT500-U4G
±3.3V
PT500-U4H
±3.3V
PT500-U4I
±3.3V
PT500-U4J
±3.3V
PT500-U4K
±3.3V
PT500-U4L
±3.3V
OUTPUT #2
V
NOM
OUTPUT #3
V
NOM
I
MAX
/I
PK
OUTPUT #4
V
NOM
I
MAX
80A
80A
80A
80A
80A
80A
80A
80A
80A
80A
80A
80A
80A
80A
80A
I
MAX
/I
PK
I
MAX
/I
PK
± 12V 12A/15A
± 15V 12A/15A
± 12V 12A/15A
± 15V 12A/15A
± 5V 12A/15A
± 5V 12A/15A
± 12V 12A/15A
± 5V 12A/15A
± 5V 12A/15A
± 5V 12A/15A
± 5V 12A/15A
± 24V
± 5V
± 12V
± 12V 12A/15A
± 15V 12A/15A
± 12V 12A/15A
± 12V 12A/15A
± 12V 12A/15A
± 15V 12A/15A
± 15V 12A/15A
± 12V 12A/15A
± 15V 12A/15A
± 24V
± 12V
± 12V
-
-
-
-
± 12V
± 24V
± 5V
± 15V
± 24V
± 5.2V
± 12V
± 5V
± 5V
± 12V
4.0A
3.0A
4.0A
4.0A
3.0A
10.0A
4.0A
10.0A
4.0A
4.0A
4A
15A
12A
4A
12A
12A
Note: Peak current ratings are for 10sec maximum. Total power not to exceed 500 watts.
Output Specifications
Parameter
Conditions
Output Power
All environmental and line conditions
Voltage Adjustment Range
Relative to nominal output voltage, all outputs
Output Regulation
Line
Load
Cross
Minimum Load
Output #1
PARD
V1, at output terminals, 20MHz B/W
Auxiliary Outputs
Min
Typ
Max
500
Units
Watts
%
%
%
%
A
mVp-p
% pk-pk
+ 5
+ 0.1
+ 0.5
+ 0.1
4
50
1
Temperature Coefficient
Environmental Specifications
Parameter
Ambient Temperature
0
0
to 50
0
C, after 30 minute warm-up
+ 0.02
%/
0
C
Conditions
Operating output de-rated linearly to 50%
of rated capacity between 50
0
C and 70
0
C
Non-operating
Operating
Non-operating
Per MIL-STD-810D, Method 516.3, Procedure
I
Per MIL-STD-810D, Method 514.3, Procedure
I
The PT500 is designed for full load operation in a 50°C ambient with 40 CFM airflow.
Min
Typ
Max
Units
0
-20
+70
+85
+10,000
+50,000
0
C
0
C
Feet
Feet
Altitude
Shock
Vibration
Cooling
Powered by ICminer.com Electronic-Library Service CopyRight 2003