SLOS073D MARCH 1976 REVISED SEPTEMBER 2004
2
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
schematic (each amplifier)
OUT
IN+
IN
VCC
VCC+
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage
(see Note 1): V
CC+
18 V
18 V
±
30 V
±
15 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
V
CC
Differential input voltage, V
ID
(see Note 2)
Input voltage, V
I
(any input, see Notes 1 and 3)
Duration of output short circuit to ground, one amplifier at a time (see Note 4)
Package thermal impedance,
θ
JA
(see Notes 5 and 6): D package
Unlimited
97
°
C/W
172
°
C/W
85
°
C/W
95
°
C/W
149
°
C/W
150
°
C
. . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
DGK package
. . . . . . . . . . . . . . . . . . . . . . . .
P package
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
PS package
. . . . . . . . . . . . . . . . . . . . . . . . . . .
PW package
. . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating virtual junction temperature, T
J
Storage temperature range, T
stg
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES:
1. All voltage values, unless otherwise noted, are with respect to the midpoint between VCC+ and VCC.
2. Differential voltages are at IN+ with respect to IN.
3. The magnitude of the input voltage must never exceed the magnitude of the supply voltage or 15 V, whichever is less.
4. Temperature and/or supply voltages must be limited to ensure that the dissipation rating is not exceeded.
5. Maximum power dissipation is a function of TJ(max),
θ
JA, and TA. The maximum allowable power dissipation at any allowable
ambient temperature is PD = (TJ(max) TA)/
θ
JA. Operating at the absolute maximum TJ of 150
°
C can affect reliability.
6. The package thermal impedance is calculated in accordance with JESD 51-7.
65
°
C to 150
°
C