Siemens
Product Manual R0002
Semiconductor Group
36
3.1
10.2.2
Absolute maximum ratings
Absolute maximum ratings are those values beyond which damage to the device may occur. Func-
tional operation under these conditions or at any other condition beyond those indicated in the oper-
ational sections of this specification is not implied:
T
A
-20 ... 85
o
C, VDD 2 ... 3.6V unless otherwise stated
10.2.3
Recommended operating conditions
The recommended operating conditions define the parameter ranges for optimal performance and
durability of the R0002.
T
A
-20 ... 85
o
C, V
DD
2 ... 3.6V unless otherwise stated
Parameter
Symbol
Min
Max
Unit
Remark
supply voltage
total power dissipation
ESD protection
latch-up protection
V
DD
-0.5
4.6
0.9
4
100
V
W
kV
mA
-4
Human Body Model
all inputs/outputs
-100
inputs
input voltage
V
Imax
-0.5V
V
DD
+0.5
V
≤
V
DDmax
outputs
output voltage
high-level output current
low-level output current
V
Omax
| I
OH
|
I
OL
Table 27: Absolute Maximum Ratings
-0.5V
V
DD
+0.5
100
150
V
≤
V
DDmax
short cut protected
short cut protected
mA
mA
Parameter
Symbol
Min
Typ
Max
Unit
Remark
supply voltage
V
DD
2.0
3.6
V
inputs
low-level input voltage
high-level input voltage
V
IL
V
IH
V
SS
-0.3
0.625 V
DD
0.25V
DD
V
DD
+0.3
V
V
outputs (push pull mode)
high-level output current
| I
OH
|
I
OL
2
mA
V
OH
V
OL
low-level output current
2
mA
clock input clk
(all values are referred to min(V
IH
) and max(V
IL
))
clock frequency data transfer mode (pp)
f
CLK
0
20
MHz
<= 10 cards,
CL
maxCMD,DAT = 100pF
,
Rpullup = 4.7k
clock frequency data transfer mode (pp)
f
CLK
0
5
MHz
<= 30 cards,
CL
maxCMD,DAT = 250pF
,
Rpullup = 1.65k
clock frequency ident. mode (od)
f
CLK
0
400
kHz
<= 30 cards,
CL
maxCMD,DAT = 250pF
,
Ropen drain = 1.65k
clock low time
clock high time
t
WL
t
WH
10
10
ns
ns
S. Figure 20
S. Figure 20
Table 28: Recommended Operating Conditions