![](http://datasheet.mmic.net.cn/300000/RP130440-3-12_datasheet_16206842/RP130440-3-12_2.png)
2
Specifications are subject to change without notice
(30.06.1999)
RP 130 ...-.-05, RP 130 ...-.-12, RP 130 ...-.-24
RP 130 240-.-..
RP 130 440-.-..
Operational voltage range
Non-rep. peak voltage
Zero voltage turn-on
Operational frequency range
Power factor
Approvals
CE-marking
24 to 280 VACrms
≥
650 V
p
≤
30 V
45 to 65 Hz
≥
0.5 @ 230 VACrms
UL, CSA, VDE
Yes
48 to 480 VACrms
≥
850 V
p
≤
50 V
45 to 65 Hz
≥
0.5 @ 400 VACrms
UL, CSA, VDE
Yes
General Specifications
RP 130 .40-.-05
RP 130 .40-.-12
RP 130 .40-.-24
Control voltage range
Control voltage
Pick-up voltage
Drop-out voltage
Input current @ rated voltage
Reverse voltage
Response time pick-up
Response time drop-out
4 to 8 VDC
5 VDC
≤
4 VDC
≥
1 VDC
≤
10 mADC
≤
6 VDC
≤
1/2 cycle
≤
1/2 cycle
8 to 16 VDC
12 VDC
≤
8 VDC
≥
1 VDC
≤
10 mADC
≤
6 VDC
≤
1/2 cycle
≤
1/2 cycle
16 to 32 VDC
24 VDC
≤
16 VDC
≥
1 VDC
≤
10 mADC
≤
6 VDC
≤
1/2 cycle
≤
1/2 cycle
Input Specifications
RP 13. .40-3-0
RP 13. .40-5-0
Operating temperature
Storage temperature
Junction temperature
R
th
junction to case
R
th
junction to ambient
-20°to +70°C (-4°to +158°F)
-40°to +100°C (-40°to +212°F)
≤
125°C (
≤
257°F)
≤
20.5 K/W
≤
33 K/W
-20°to +70°C (-4°to +158°F)
-40°to +100°C (-40°to +212°F)
≤
125°C (
≤
257°F)
≤
15.6 K/W
≤
21 K/W
Thermal Specifications
Output Specifications
RP 130 .40-3-0
RP 130 .40-5-0
Rated operational current AC 1
3 Arms
5 Arms
3 Arms
20 mArms
≤
12 A
p
90 A
p
AC 3 2.5 Arms
20 mArms
≤
6 A
p
Minimum operational current
Rep. overload current t=1 s
Non-rep. surge current t=20 ms 60 A
p
Off-state leakage current
@ rated voltage and frequency
I
2
t for fusing t=1-10 ms
Critical dI/dt
On-state voltage drop
@ rated current
Critical dV/dt commutating
Critical dV/dt off-state
≥
100 V/μs
≥
100 V/μs
≤
1 mArms
≤
18 A
2
s
≥
20 A/ms
≤
1 mArms
≤
40 A
2
s
≥
20 A/ms
≤
1.2 Vrms
≥
100 V/μs
≤
1.2 Vrms
≥
100 V/μs