Weight
Housing material
Terminals
Potting compound
Approx. 10 g
Noryl GFN 1, black
Copper, tin-plated
Flame retardant polyurethane
Housing Specifications
Accessories
Fuses and varistors:
For further information refer to “General Accessories”.
RP 130 .40-.-0
RP 132 .40-.-0
Control voltage range
Pick-up voltage
Drop-out voltage
Reverse voltage
Response time pick-up
Response time drop-out
Input impedance
3 to 32 VDC
≤
3 VDC
≥
1 VDC
≤
6 VDC
≤
1/2 cycle
≤
1/2 cycle
1.5 k
3 to 32 VDC
≤
3 VDC
≥
1 VDC
≤
6 VDC
≤
1 ms
≤
1/2 cycle
1.5 k
Input Specifications
Output Specifications
RP 13. .40-2-0
RP 13. .40-4-0
Rated operational current AC 1
2 Arms
2 Arms
20 mArms
≤
6 A
p
42 A
p
4 Arms
3 Arms
20 mArms
≤
12 A
p
90 A
p
AC 3
Minimum operational current
Rep. overload current t=1 s
Non-rep. surge current t=20 ms
Off-state leakage current
@ rated voltage and frequency
I
2
t for fusing t=1-10 ms
Critical dl/dt
On-state voltage drop
@ rated current
Critical dV/dt commutating
Critical dV/dt off-state
≤
5 mArms
≤
9 A
2
s
≥
10 A/μs
≤
5 mArms
≤
40 A
2
s
≥
10 A/μs
≤
1.6 Vrms
≥
4 V/μs
≥
100 V/μs
≤
1.6 Vrms
≥
4 V/μs
≥
100 V/μs
RP 130 ...-.-., RP 132 ...-.-.
Thermal Specifications
RP 13. .40-2-0
RP 13. .40-4-0
Operating temperature
Storage temperature
Junction temperature
R
th
junction to case
R
th
junction to ambient
-20°to +70°C (-4°to +158°F)
-40°to +100°C (-40°to +212°F)
≤
125°C (
≤
257°F)
≤
20.5 K/W
≤
37.5 K/W
-20°to +70°C (-4°to +158°F)
-40°to +100°C (-40°to +212°F)
≤
125°C (
≤
257°F)
≤
15.6 K/W
≤
22.5 K/W
Insulation Input-Output
Rated insulation voltage
Insulation resistance
Insulation capacitance
Reference voltage
according to VDE 01 10 B
Insulation group C
≥
4000 VACrms
≥
10
10
≤
8 pF
500 VACrms, 600 VDC
Applications
These relays can be used to
switch heaters, motors, lights,
valves or solenoids.
When used at full load cur-
rent, the relays must be placed
vertically. If more than one
relay is mounted, please al-
low a minimum distance of 20
mm in between for sufficient
air cooling.