RS-422/485 Application Note
23
B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350
PH (815) 433-5100 -- FAX (815) 434-7094
Chapter 4: Transient Protection of RS-422 and RS-485
Systems
The first step towards protecting an RS-422 or RS-485 system from
transients is understanding the nature of the energy we are guarding against.
Transient energy may come from several sources, most typically environmental
conditions or induced by switching heavy inductive loads.
What does a surge look like
Surge Specifications
While transients may not always conform to industry specifications, both
the Institute of Electrical and Electronics Engineers (IEEE) and the
International Electrotechnical Commission (IEC) have developed transient
models for use in evaluating electrical and electronic equipment for immunity
to surges. These models can offer some insight into the types of energy that
must be controlled to prevent system damage.
Both IEC 1000-4-5: 1995 “Surge Immunity Test” and IEEE C62.41-1991
“IEEE Recommended Practice on Surge Voltages in Low-Voltage AC Power
Circuits” define a “1.2/50
μ
s - 8/20
μ
s combination wave” surge which has a 1.2
μ
s voltage rise time with a 50
μ
s decay across an open circuit. The specified
current waveform has an 8
μ
s rise time with a 20
μ
s decay into a short circuit.
Open circuit voltages levels from 1 to 6 kV are commonly used in both the
positive and negative polarities, although under some circumstances voltages as
high as 20 kV may be applied. Figures 4.1 and 4.2 illustrate the combination
wave characteristics. In addition, IEEE C62.41 also specifies a 100 kHz “ring
wave” test. The ring wave has a 0.5
μ
s rise time and a decaying oscillation at
100 kHz with source impedance of 12
as shown in Figure 4.3. Typical
amplitudes for the 100 kHz ring wave also range from 1 – 6 kV.
相關(guān)PDF資料
PDF描述
RS-485 RS-422 AND RS-485 APPLICATION NOTE
RS-MK-X2010 High Integrity FM Transceiver
RS3FS SDR Cable Assembly; Connector Type A:micro D Ribbon Plug; Connector Type B:micro D Ribbon Plug; Cable Length:2m; No. of Contacts:26; Pitch Spacing:0.8mm RoHS Compliant: Yes
RS3FS Damper Diodes (For TV)
RS4FS SDR Cable Assembly; Connector Type A:micro D Ribbon Plug; Connector Type B:micro D Ribbon Plug; Cable Length:5m; No. of Contacts:26; Pitch Spacing:0.8mm RoHS Compliant: Yes
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
RS422-GE1 制造商:Carlo Gavazzi 功能描述:CABLE FOR GE90
RS422-MI1 制造商:Carlo Gavazzi 功能描述:CABLE FOR MITS MASTER
RS422-MI2 制造商:Carlo Gavazzi 功能描述:CABLE FOR MITS MASTER
RS422-MI3 制造商:Carlo Gavazzi 功能描述:CABLE FOR MITS MASTER
RS422-OM2 制造商:Carlo Gavazzi 功能描述:CABLE FOR OMRON MASTER