![](http://datasheet.mmic.net.cn/190000/S238B-N-M-0_datasheet_14975584/S238B-N-M-0_1.png)
SINGLE-POLE DOUBLE-THROW SWITCHES
FEATURES
Multioctave bands 0.2 to 18 GHz
Current and TTL control
Low loss
High isolation
Medium and high speed models
Drop-in models
Amplitude and phase tracking
Frequency
Insertion
Type
DC Power Consumption
Range
Model
Loss
Isolation
*VSWR
(Reflective/
Pos. Supply Neg. Supply
Ordering
Additional
(GHz)
Number
(dB, Max.)
(dB, Min.)
(Max.)
Absorptive)
(mA, Max.) (mA, Min.)
Outline
Options
Features
STANDARD, MULTIOCTAVE BAND MODELS
S203A
1.2
50
1.6:1
Ref
60
SP2T
1-5
–
S203B
1.5
70
1.6:1
Ref
60
SP2T
1-5
–
0.2–2
N203A
1.7
55
1.6:1
Abs
60
SP2T
1-5
–
N203B
2
75
1.6:1
Abs
60
SP2T
1-5
–
S213A
1
60
1.6:1
Ref
60
SP2T
1-5
–
0.5–2
S213B
1.3
80
1.6:1
Ref
60
SP2T
1-5
–
N213A
1.5
55
1.6:1
Abs
60
SP2T
1-5
–
N213B
1.8
75
1.6:1
Abs
60
SP2T
1-5
–
S236A
1.6
60
1.7:1
Ref
60
SP2T
1-5
–
2–8
S236B
1.8
80
1.7:1
Ref
60
SP2T
1-5
–
N236A
1.8
55
1.7:1
Abs
60
SP2T
1-5
–
N236B
2
70
1.7:1
Abs
60
SP2T
1-5
–
S247A
2
70
1.7:1
Ref
60
SP2T
1-5
–
4–12
S247B
2.2
90
1.7:1
Ref
60
SP2T
1-5
–
N247A
2
50
1.7:1
Abs
60
SP2T
1-5
–
N247B
2.2
65
1.7:1
Abs
60
SP2T
1-5
–
S238A
2.5
60
2:1
Ref
60
SP2T
1-5
–
2–18
S238B
2.8
80
2:1
Ref
60
SP2T
1-5
–
N238A
2.6
45
2:1
Abs
60
SP2T
1-5
–
N238B
3
60
2:1
Abs
60
SP2T
1-5
–
S228A
2.6
55
2:1
Ref
60
SP2T
1-5
–
1–18
S228B
3
70
2:1
Ref
60
SP2T
1-5
–
N228A
2.8
45
2:1
Abs
60
SP2T
1-5
–
N228B
3.2
60
2:1
Abs
60
SP2T
1-5
–
Electrical performance of multioctave models can be optimized over narrower bandwidths, or for a particular parameter. Electrical options include: Lower
insertion loss, lower VSWR, higher isolation, flat amplitude response, amplitude tracking. Mechanical/Control options include: Custom packaging, single
supply operation, fast switching time, single TTL control line. Examples of custom models previously shipped are shown below. Consult factory for options.
OPTIMIZED PERFORMANCE MODELS
0.5–2
124513
1.4
70
1.5:1
Ref
–
SP2T
50ns switch speed
0.5–2
126157
1.5
70
1.6:1
Abs
95
Contact factory
5V,-12V. 50ns switch speed
1–2
126158
1.5
70
1.5:1
Ref
90
Contact factory
5V,-12V. Single TTL line
1.2–1.6
122797
2.2
75
1.6:1
Abs
60
SP2T
5V,-15V. 50ns switch speed
0.8–4
126150
1.5
70
1.7:1
Ref
60
SP2T
5V,-12V
8–10
122499
2
60
1.6:1
Ref
–
SP2T
5V,-12V. 50ns switch speed
9–11
126154
2.5
40
1.5:1
Ref
25
–
Contact factory
Single 5V supply
15–17
125963
3
45
2:1
Ref
60
SP2T
5V,-12V. 50ns switch speed
2–18
124080
2.7
65
2:1
Ref
60
SP2T
5V,-12V. 50ns switch speed
2–18
124784
3
65
2:1
Abs
60
SP2T
5V,-12V. Single TTL line
2–18
127070
2.5
70
1.7:1
Abs
60
SP2T
5V,-15V
23.5–24.5
120612
3
35
2:1
Ref
–
SP2T
5V,-12V. 7ns rise/fall time
*For reflective models, VSWR is not specified in the “OFF” state.
For absorptive models, VSWR in the “OFF” state is defined for port J2 only.