Switch mode Power Supply
S82K
L-11
P
S
90-/100-/240W models with PFC (S82K-P
@@@
24 models)
Note: 1.
Defined with a 100% load and the rated input voltage (100 or 200 VAC)
2.
Do not press down on the terminal block with a force exceeding 75 N while tightening the terminals.
3.
To ensure the Emission Enclosure ratings, a noise filter should be used on the output lines at the closest point. (90- and 100-W models:
S82Y-JF6-N)
4.
To ensure the Emission Enclosure rating, a ferrite ring core should be used on all cables.
5.
To meet Class-2 requirements with the 100-W model, either a fuse or circuit breaker that is UL listed or CSA certified, and rated at 4.2 A
max. should be wired in series with the load to be connected to the power supply. Only then can the power supply output be considered
as meeting Class 2.
Item
Single output
100 W
90 W
240 W
Other
Ambient temperature
Operating: See the derating curve in the Engineering Data section (No condensation or icing)
Storage:
25
°
C to 65
°
C (no condensation or icing)
Operating: 25% to 85%
Storage:
25% to 90%
3,000 VAC at 50/60 Hz for 1 min. (between all inputs and outputs)
2,000 VAC at 50/60 Hz for 1 min. (between all inputs and GR terminal)
1,000 VAC at 50/60 Hz for 1 min. (between all outputs and GR terminal)
Alarm current: 20 mA (90- and 100-W models) 25 mA (240-W models)
100 M
min. at 500 VDC (between all outputs and all inputs/GR terminal)
Malfunction: 10 to 55 Hz, 0.375-mm single amplitude for 2
hrs each in X, Y, and Z directions
Ambient humidity
Dielectric strength
Insulation resistance
Vibration resistance
Malfunction: 10 to 55 Hz, 0.15-mm single
amplitude for 2 hrs each in
X, Y, and Z directions
Malfunction: 300 m/s
2
, 3 times each in
±
X,
±
Y, and
±
Z directions
Shock resistance
Malfunction: 150 m/s
2
, 3 times each in
±
X,
±
Y, and
±
Z direc-
tions
Screw tightening torque
0.74 N
m max. (see note 2)
Output indicator
Yes (Green)
Electromagnetic inter-
ference
(see note 1)
EMC (see note 3, 4)
90-, 100-W Models
(EMI):
Harmonic Current:
Emission Enclosure:
Emission AC Mains:
Emission Output Ports: EN55022 class A (with a recommended optional filter) (see note 3)
240-W Model
(EMI):
EN50081-2
Harmonic Current:
EN61000-3-2
Emission Enclosure:
EN55011 class A (see note 4)
Emission AC Mains:
EN55011 class A
Common to All Models
(EMS):
EN50082-2
Immunity ESD:
EN61000-4-2: 4-kV contact discharge (level 2)
Conforms to FCC class A
EN50081-1
EN61000-3-2 (200 VAC input only)
EN55022 class B
EN55022 class B
8-kV air discharge (level 3)
Immunity Burst:
EN61000-4-4: 2-kV power-line (level 3)
2-kV output line (level 4)
EN61000-4-5: between 2-kV lines (except for 240-W models)
between 4-kV line and FG (except for 240-W models)
Class 2 (UL1310)/Class 2 (CSA C22.2 No. 950) (see note 5)
UL508 (Listing)/1950
CSA C22.2 No. 14/No. 950, EN50178 (VDE0160), EN60950
Conforms to VDE0106/P100
1,000 g max.
Immunity Surge:
Approved standards
UL508 (Listing)/1012
CSA C22.2 No. 14/E.B. 1402C, EN50178
(VDE0160), EN60950, Conforms to
VDE0106/P100
2,200 g max.
Weight