Microsemi
Scottsdale Division
8700 E. Thomas Rd. PO Box 1390, Scottsdale, AZ 85252 USA, (480) 941-6300, Fax: (480) 947-1503
Page 2
Copyright
2001
MSCXXXX.PDF 4-07-03 REV A
W
M
.
C
SMAJ4460 thru SMAJ4496
and SMAJ6485 thru SMAJ6491
1.5 Watt Zener Diodes
S C O T T S D A L E
DIVISION
S
S
E LE CT RICAL CHARACT E RIS T ICS @ 25 °C (unless otherw ise spec ified)
MICROSEMI
PART NUMBER
ZENER
VOLTAGE
V
Z
@ I
ZT
VOLTS
NOM.
TEST
CURRENT
I
ZT
mA
DYNAMIC
IMPEDANCE
Z
ZT
= I
ZT
OHMS
MAX
10
10
9
9
8
7
5
4
2.5
2.5
3
4
5
6
7
8
9
10
11
12
14
16
18
20
25
27
30
40
50
60
70
80
100
130
160
200
250
300
400
500
700
1000
1300
1500
KNEE
IMPEDANCE
Z
ZK
= I
ZK
OHMS
MAX
400
400
400
400
500
500
600
200
200
400
400
500
500
550
550
550
600
600
650
650
650
700
700
750
800
850
900
950
1000
1100
1300
1500
1700
2000
2500
3000
3100
4000
4500
5000
6000
6500
7000
8000
TEST
CURRENT
I
ZK
mA
REVERSE
CURRENT
I
R
@ V
R
μA
MAX
50
50
35
5
4
1
.50
10
5
1
.50
.30
.30
.30
.20
.05
.05
.05
.05
.05
.05
.05
.05
.05
.05
.05
.05
.05
.05
.05
.025
.025
.025
.025
.025
.025
.025
.025
.025
.025
.025
.025
.025
.025
TEST
VOLTAGE
V
R
VOLTS
MAXIMUM
CONTINOUS
CURRENT
mA
MAXIMUM
SURGE
CURRENT at
8.3 ms square
wave
T
A
= 25 °C
A
-
-
-
-
-
-
-
-
10
9
7.8
6.8
6
5.2
4.8
4.4
3.6
3.2
2.8
2.4
2.2
1.8
1.6
1.5
1.32
1.20
1.08
.96
.90
.84
.78
.70
.64
.58
.52
.46
.40
.38
.36
.32
.28
.24
.20
.16
MAXIMUM
SURGE
CURRENT at
8.3 ms square
wave
T
A
= 100 °C
A
8.4
7.8
7.2
6.6
6.0
5.4
5
4.6
4.2
3.8
3.4
3.2
2.8
2.6
2.4
2.2
1.9
1.6
1.58
1.42
1.3
1.2
1.06
.96
.86
.80
.74
.66
.60
.56
.52
.46
.42
.38
.34
.32
.28
.26
.24
.22
.19
.178
.158
.144
SMAJ6485
SMAJ6486
SMAJ6487
SMAJ6488
SMAJ6489
SMAJ6490
SMAJ6491
SMAJ4460
SMAJ4461
SMAJ4462
SMAJ4463
SMAJ4464
SMAJ4465
SMAJ4466
SMAJ4467
SMAJ4468
SMAJ4469
SMAJ4470
SMAJ4471
SMAJ4472
SMAJ4473
SMAJ4474
SMAJ4475
SMAJ4476
SMAJ4477
SMAJ4478
SMAJ4479
SMAJ4480
SMAJ4481
SMAJ4482
SMAJ4483
SMAJ4484
SMAJ4485
SMAJ4486
SMAJ4487
SMAJ4488
SMAJ4489
SMAJ4490
SMAJ4491
SMAJ4492
SMAJ4493
SMAJ4494
SMAJ4495
SMAJ4496
3.3
3.6
3.9
4.3
4.7
5.1
5.6
6.2
6.8
7.5
8.2
9.1
10
11
12
13
15
16
18
20
22
24
27
30
33
36
39
43
47
51
56
62
68
75
82
91
100
110
120
130
150
160
180
200
76.0
69.0
64.0
58.0
53.0
49.0
45.0
40.0
37.0
34.0
31.0
28.0
25.0
23.0
21.0
19.0
17.0
15.5
14.0
12.5
11.5
10.5
9.5
8.5
7.5
7.0
6.5
6.0
5.5
5.0
4.5
4.0
3.7
3.3
3.0
2.8
2.5
2.0
2.0
1.9
1.7
1.6
1.4
1.2
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
0.5
0.5
0.5
.25
.25
.25
.25
.25
.25
.25
.25
.25
.25
.25
.25
.25
.25
.25
.25
.25
.25
.25
.25
.25
.25
.25
.25
.25
.25
.25
.25
.25
.25
.25
.25
1.0
1.0
1.0
1.0
1.0
1.0
2.0
3.72
4.08
4.50
4.92
5.46
8.0
8.8
9.6
10.4
12.0
12.8
14.4
16.0
17.6
19.2
21.6
24.0
26.4
28.8
31.2
34.4
37.6
40.8
44.8
49.6
54.4
60.4
65.6
72.8
80.0
88.0
96.0
104
120
128
144
160
433
397
366
332
304
280
255
230
210
191
174
157
143
130
119
110
95
90
79
71
65
60
53
48
43
40
37
33
30
28
26
23
21
19
17
16
14
13
12
11
9.5
8.9
7.9
7.2
Notes:
1.
2.
3.
No suffix indicates a ±5% tolerance on nominal V
Z
, C denotes a ±2% tolerance, and D denotes a ±1% tolerance.
Zener voltage (V
z
) is measured at T
L
= 30 °C. Voltage measurement to be performed 90 seconds after application of dc current.
The zener impedance is derived from the 60 Hz ac voltage which results when an ac current having an rms value equal to 10% of the
dc zener current (I
or I
).
4. V
f
at 200 mA 1.2 volts maximum and V
f
at 1.0 A 1.5 volts maximum.