SN55107A, SN55107B, SN55108A, SN55108B
SN75107A, SN75107B, SN75108A, SN75108B
DUAL LINE RECEIVERS
SLLS069B – JANUARY 1977 – MAY 1995
2–3
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
schematic (each receiver)
To Other Receiver
Output Y
GND
Strobe G
Strobe S
4, 9
7
5, 8
6
800
Common
to Both
Receivers
1 k
1 k
400
4 k
1.6 k
120
4.8 k
760
R
4.25 k
3 k
3 k
13
2, 11
1, 12
14
VCC +
A
B
Inputs
VCC –
Pin numbers shown are for D, J, N, and W packages.
R = 1 k
for ’107A and ’107B, 750
for ’108A and ’108B.
NOTES:
1. Resistor values shown are nominal.
2. Components shown with dashed lines in the output circuitry are applicable to the ’107A and ’107B only. Diodes in series with the
collectors of the differential input transistors are short circuited on ’107A and ’108A.
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, V
CC+
(see Note 3)
Supply voltage, V
CC–
Differential input voltage, V
ID
(see Note 4)
Common-mode input voltage, V
IC
(see Note 5)
Strobe input voltage
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous total dissipation
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating free-air temperature range, T
A
: SN55’
SN75’
Storage temperature range, T
stg
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Case temperature for 60 seconds, T
c
: FK package
Lead temperature 1,6 mm (1/16 inch) from case for 60 seconds: J package
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds: D, N, or W package
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES:
3. All voltage values, except differential voltages, are with respect to network ground terminal.
4. Differential voltage values are at the noninverting (A) terminal with respect to the inverting (B) terminal.
5. Common-mode input voltage is the average of the voltages at the A and B inputs.
7 V
–7 V
±
6 V
±
5 V
5.5 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
See Dissipation Rating Table
–55
°
C to 125
°
C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
0
°
C to 70
°
C
–65
°
C to 150
°
C
260
°
C
300
°
C
260
°
C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . .