SN55113, SN75113
DUAL DIFFERENTIAL LINE DRIVERS
SLLS070C – SEPTEMBER 1973 – REVISED MARCH 1997
3
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
schematic
1ZP
V
V
V
AND
Pullup
1YP
9
4 k
1 k
900
100
5 k
90
500
Input 1B
6
1YS
OSink
AND
4
3
100
Output
Control
1C
4 k
1.6 k
1 k
8
GND
Common Output
Control CC
Output Control 2C
Input 2A
9
10
11
12
13
AND Pullup 2YP
AND Output 2YS
15
14
NAND Pullup 2ZP
NAND Output 2ZS
333
100
500
90
900
600
600
5 k
4 k
600
1 k
To
Other
Driver
Input 1A
5
4 k
9
100
VCC
Pullup
1ZS
Output
NAND
16
2
1
V ... VCC bus
7
These components are common to both drivers. Resistor values shown are nominal and in ohms.
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, V
CC
(see Note 1)
Input voltage, V
I
Off-state voltage applied to open-collector outputs
Continuous total power dissipation (see Note 2)
Operating free-air temperature range, T
A
: SN55113
7 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SN75113
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range, T
stg
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds: N package
Case temperature for 60 seconds: FK package
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lead temperature 1,6 mm (1/16 inch) from case for 60 seconds: J or W package
5.5 V
12 V
See Dissipation Rating Table
–55
°
C to 125
°
C
0
°
C to 70
°
C
–65
°
C to 150
°
C
260
°
C
260
°
C
300
°
C
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
DISSIPATION RATING TABLE
PACKAGE
TA
≤
25
°
C
POWER RATING
DERATING FACTOR
ABOVE TA = 25
°
C
11.0 mW/
°
C
11.0 mW/
°
C
9.2 mW/
°
C
8.0 mW/
°
C
TA = 70
°
C
POWER RATING
TA = 125
°
C
POWER RATING
FK
1375 mW
880 mW
275 mW
J
1375 mW
880 mW
275 mW
N
1150 mW
736 mW
N/A
W
1000 mW
640 mW
200 mW