5
SP207EDS/09
SP207E Series High Performance Transceivers
Copyright 2000 Sipex Corporation
FEATURES
As in the original RS-232 multi-channel
products, the
SP207E Series
multi–channel
RS-232 line transceivers provide a variety of
configurations to fit most communication
needs, especially those applications where +12V
is not available. All models in this Series feature
low–power CMOS construction and
SIPEX
–
proprietary on-board charge pump circuitry to
generate the +10V RS-232 voltage levels. The
ability to use 0.1
μ
F charge pump capacitors
saves board space and reduces circuit cost.
Different models within the Series provide
different driver/receiver combinations to
match any application requirement.
The
SP211
and
SP213E
models feature a low–
power shutdown mode, which reduces power
supply drain to 1
μ
A. The
SP213E
includes a
Wake-Up function which keeps two receivers
active in the shutdown mode, unless disabled by
the EN pin.
The family is available in 28–pin SO (wide) and
SSOP (shrink) small outline packages. Devices
can be specified for commercial (0
°
C to +70
°
C)
and industrial/extended (–40
°
C to +85
°
C)
operating temperatures.
THEORY OF OPERATION
The
SP207E Series
devices are made up of
three basic circuit blocks — 1) transmitter/
driver, 2) receiver and 3) the
SIPEX
–
proprietary charge pump. Each model within
the Series incorporates variations of these
circuits to achieve the desired configuration
and performance.
Charge–Pump
The charge pump is a
Sipex
–patented design
(5,306,954) and uses a unique approach
compared to older less–efficient designs. The
charge pump still requires four external capacitors,
but uses a four–phase voltage shifting technique
to attain symmetrical 10V power supplies.
Figure 3a
shows the waveform found on the
positive side of capcitor C
, and
Figure 3b
shows the negative side of capcitor C
. There is
a free–running oscillator that controls the four
phases of the voltage shifting. A description of
each phase follows.
Phase 1
— V
charge storage —During this phase of the
clock cycle, the positive side of capacitors C
1
and C
are initially charged to +5V. C
switched to ground and the charge in C
transferred to C
+5V, the voltage potential across capacitor C
2
is
now 10V.
+
is then
–
is
–
. Since C
+
is connected to
Phase 2
— V
transfer — Phase two of the clock
connects the negative terminal of C
to the V
SS
storage capacitor and the positive terminal of C
2
to ground, and transfers the generated –l0V to
C
. Simultaneously, the positive side of
capacitor C
is switched to +5V and the negative
side is connected to ground.
Phase 3
— V
charge storage — The third phase of the
clock is identical to the first phase — the charge
transferred in C
produces –5V in the negative
terminal of C
, which is applied to the negative
side of capacitor C
. Since C
voltage potential across C
2
is l0V.
+
is at +5V, the
V
CC
= +5V
–5V
–5V
+5V
V
SS
Storage Capacitor
V
DD
Storage Capacitor
C
1
C
2
C
3
C
4
+
+
+
+
–
–
–
–
Figure 1. Charge Pump — Phase 1