3284PS 2704 - SX21V001-Z4 - 3
June 29, '99
4-1/1
4. ABSOLUTE MAXIMUM RATINGS
4. 1 ELECTRICAL ABSOLUTE MAXIMUM RATINGS
ITEM
Note 1 DISP OFF, FLM, CL1, CL2, UD0
~
UD7, LD0
~
LD7
Note 2 Make certains you are grounded when handling LCM
4. 2 ENVIRONMENTAL ABSOLUTE MAXIMUM RATINGS
ITEM
Note 1 Ta<40
°
C : 85%RH max.
Ta>40
°
C : Absolute humidity must be lower than the humidity of 85%RH at 40
°
C.
Note 2 Ta at -20
°
C ---------- <48h, at 60
°
C ---------- <168h
Note 3 Background color changes slightly depending on ambient temperature.
This phenomenon is reversible.
Note 4 5Hz
~
100Hz (Except resonance frequency)
Note 5 This module should be operated normally after finish the test.
Note 6 When LCM is operated at 5°C, the life time of CFL will be reduced.
Need to make sure of value of IL and characteristics of inverter.
Also the response time at 5°C will be slower.
Ambient Temperature
Humidity
Vibration
Shock
Corrosive Gas
OPERATING
MIN
5
°
C
Note 1
-
-
Not Acceptable
MAX
40
°
C
2.45 m/s
2
(0.25G)
29.4 m/s
2
(3G)
STORAGE
MIN
-20
°
C
Note 1
-
-
Not Acceptable
MAX
60
°
C
11.76 m/s
2
(1.2G)
Note 5
490 m/s
2
(50G)
Note 5
COMMENT
Note 2, 3
Without condensation
Note 4
XYZ directions 11ms
VSS=0V:Standard
UNIT
V
V
V
A
-
Pow er Supply for Logic
Contrast Adjustment Voltage
Input Voltage
Input Current
Static Electricity
SYMBOL
VDD-VSS
VCON-VSS
Vi
Ii
-
MIN
0
0
-0.3
0
-
MAX
6.0
VDD
VDD+0.3
1
-
COMMENT
Note 1
Note 2
Displays,
Hitachi, Ltd.
Sh.
No.
Page
Date