3
SY10E416
SY100E416
Micrel, Inc.
M9999-032206
hbwhelp@micrel.com or (408) 955-1690
TA = 0
°CTA = +25°CTA = +85°C
Symbol
Parameter
Min.
Typ.
Max.
Min.
Typ.
Max.
Min.
Typ.
Max. Unit
Condition
tPD
Propagation Delay to Output
ps
—
D (Diff)
250
350
500
250
350
500
250
350
500
D (SE)
200
350
550
200
350
550
200
350
550
tskew
Within-Device Skew
—
50
—
50
—
50
—
ps
1
tskew
Duty Cycle Skew, tPLH–tPHL
±10
ps
2
VPP (AC)
Minimum Input Swing
150
—
150
—
150
—
mV
3
tr
Rise/Fall Time
100
200
350
100
200
350
100
200
350
ps
—
tf
20–80%
TA = 0
°CTA = +25°CTA = +85°C
Symbol
Parameter
Min.
Typ.
Max.
Min.
Typ.
Max.
Min.
Typ. Max.
Unit
Condition
VBB
Output Reference Voltage
V—
10E
–1.38
—
–1.27 –1.35
—
–1.25 –1.31
—
–1.19
100E
–1.38
—
–1.26 –1.38
—
–1.26 –1.38
—
–1.26
IIH
Input HIGH Current
—
150
—
150
—
150
A—
IEE
Power Supply Current
mA
—
10E
—
135
162
—
135
162
—
135
162
100E
—
135
162
—
135
162
—
155
186
VPP (DC)
Input Sensitivity
50
—
50
—
50
—
mV
1
VCMR
Common Mode Range
–1.5
—
0
–1.5
—
0
–1.5
—
0
V
2
DC ELECTRICAL CHARACTERISTICS
VEE = VEE (Min.) to VEE (Max.); VCC = VCCO = GND
Notes:
1. Differential input voltage required to obtain a full ECL swing on the outputs.
2. VCMR is referenced to the most positive side of the differential input signal. Normal operation is obtained when the input signals are within the VCMR range
and the input swing is greater than VPP (min.) and <1V.
AC ELECTRICAL CHARACTERISTICS
VEE = VEE (Min.) to VEE (Max.); VCC = VCCO = GND
Notes:
1. Within-device skew is defined as identical transitions on similar paths through a device.
2. Duty cycle skew defined only for differential operation when the delays are measured from the cross point of the inputs to the cross point of the outputs.
3. Minimum input swing for which AC parameters are guaranteed.