http://www.tracopower.com
Page 2 of 3
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
Input Specifications
Input current no load /full load
Start-up voltage /
under voltage shut down
Surge voltage
(1 sec. max.)
Reverse voltage protection
Conducted noise
(input)
Output Specifications
Voltage set accuracy
Regulation
Ripple and noise
(20 MHz Bandwidth)
Temperature coefficient
Output current limitation
Short-circuit protection
Capacitive load
General Specifications
Temperature ranges
Derating
Humidity
(non condensing)
Reliability, calculated MTBF (MIL-HDBK-217 E)
Isolation voltage
Isolation capacity
Isolation resistance
Switching frequency
Safety standards
Safety approval
5 Vin models
50 mA / 1460 mA typ.
12 Vin models
20 mA / 590 mA typ.
24 Vin models
5 mA / 290 mA typ.
48 Vin models
3 mA / 145 mA typ.
5 Vin models
4.4 VDC / 4.0 VDC
12 Vin models
8.0 VDC / 8.0 VDC
24 Vin models
16.0 VDC / 16.0 VDC
48 Vin models
32.0 VDC / 32.0 VDC
5 Vin models
10 V max.
12 Vin models
25 V max.
24 Vin models
50 V max.
48 Vin models
100 V max.
1.0 A max.
EN 55022 level A, FCC part 15, level A
– Input variation Vin min. to Vin max.
– Load variation 10 – 100 %
– single output models
– dual output models balanced load
– dual output models unbalanced load
1 %
0.3 % max.
1 % max.
1 % max.
3 % max.
50 mVpk-pk max.
± 0.02 % /K
>120 % of Iout max., constant current
indefinite (automatic recovery)
6800 μF max.
1000 μF max.
(each output)
– single output models
– dual output models
– Operating
– Case temperature
– Storage
– 40 °C ... + 85 °C
+ 100 °C max.
– 55 °C ... + 125 °C
3.5% /K above 70°C
95 % rel H max.
>1 Mio. h @ + 25 °C
1’500 VDC
380 pF typ.
> 1‘000 M Ohm
300 kHz typ. (Pulse frequency modulation PFM)
UL 60950, IEC 60950, EN 60950
Compliance up to 60 VDC input voltage
(SELV limit)
UL /cUL File E188913
(5Vin models pending)
Input/Output
Input/Output
Input/Output (500 VDC)
DC/DC Converters
TEN 5 Series
6 Watt