TGA83
10-SCC
4
ABSOLUTE
MAXIMUM RATINGS
Drain supply voltage, V
D
........................................................................................................................
Positive supply voltage, V
+
..................................................................................................................
Positive supply voltage range with respect to negative supply voltage, V
+
-
V
G1
..............................
Positive supply voltage range with respect to gain control voltage, V
CTR L
-
V
+
..............................
Negative supply voltage range, V
G1
..............................................................................................
Gain control voltage range, V
CTRL
................................................................................................
Drain supply current, I
D
........................................................................................................................
Positive supply current, I
+
..............................................................................................................
Power dissipation, P
D
, at (or below) 25
°
C base-plate temperature* ......................................................
Input continuous wave power, P
IN
....................................................................................................
Operating channel temperature, T
CH
** ..............................................................................................
Mounting temperature (30 sec), T
M
....................................................................................................
Storage temperature range, T
STG
............................................................................................
9 V
12V
0 V to 13 V
0 V to
-
13 V
-
5 V to 0 V
-
5 V to 4 V
I
DSS
188 mA
2.6W
23 dBm
150
°
C
320
°
C
-
65 to 150
°
C
Ratings over operating channel temperature range, T
CH
(unless otherwise noted)
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device.
These are stress ratings only, and functional operation of the device at these or any other conditions beyond
those indicated under “RF Characteristics” is not implied. Exposure to absolute maximum rated conditions for
extended periods may affect device reliability.
* For operation above 25
°
C base - plate temperature, derate linearly at the rate of 5.5 mW/
°
C.
** Operating channel temperature directly affects the device MTTF . For maximum life, it is recommended that
channel temperature be maintained at the lowest possible level.
TriQuint Semiconductor, Inc.
Texas Facilities
(972) 995-8465
www.triquint.com