TSL201RLF
64 1 LINEAR SENSOR ARRAY
TAOS077B
MAY 2007
3
The
LUMENOLOGY
Company
Copyright 2007, TAOS Inc.
www.taosinc.com
Absolute Maximum Ratings
Supply voltage range, V
DD
Input voltage range, V
I
Input clamp current, I
IK
(V
I
< 0 or V
I
> V
DD
)
Output clamp current, I
OK
(V
O
< 0 or V
O
> V
DD
)
Voltage range applied to any output in the high impedance or
power-off state, V
O
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous output current, I
O
(V
O
= 0 to V
DD
)
Continuous current through V
DD
or GND
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Analog output current range, I
O
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating free-air temperature range, T
A
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range, T
stg
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds
ESD tolerance, human body model
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
0.3 V to 6 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
0.3 V to V
DD
+ 0.3V
20 mA to 20 mA
25 mA to 25 mA
0.3 V to V
DD
+ 0.3V
25 mA to 25 mA
40 mA to 40 mA
25 mA to 25 mA
25
°
C to 85
°
C
25
°
C to 85
°
C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
260
°
C
2000 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “Recommended Operating Conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
Not recommended for solder reflow.
Recommended Operating Conditions (see Figure 1 and Figure 2)
MIN
4.5
NOM
MAX
5.5
V
DD
V
DD
0.8
1000
5000
100
70
UNIT
V
V
V
V
nm
kHz
ms
°
C
Supply voltage, V
DD
Input voltage, V
I
High-level input voltage, V
IH
Low-level input voltage, V
IL
Wavelength of light source,
λ
Clock frequency, f
clock
Sensor integration time, t
int
Operating free-air temperature, T
A
Load resistance, R
L
Load capacitance, C
L
5
0
2
0
400
5
0.017
0
300
4700
Ω
470
pF