TSL245R
INFRARED LIGHT-TO-FREQUENCY CONVERTER
TAOS060D
SEPTEMBER 2007
2
Copyright 2007, TAOS Inc.
The
LUMENOLOGY
Company
www.taosinc.com
Terminal Functions
TERMINAL
NAME
GND
OUT
V
DD
TYPE
DESCRIPTION
NO.
1
3
2
Power supply ground (substrate). All voltages are referenced to GND.
Output voltage.
Supply voltage.
O
Absolute Maximum Ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, V
DD
(see Note 1)
Operating free-air temperature range, T
A
Storage temperature range, T
stg
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds (S Package)
Reflow solder, in accordance with J-STD-020C or J-STD-020D (SM Package)
6 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
25
°
C to 70
°
C
25
°
C to 85
°
C
260
°
C
260
°
C
. . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: All voltage values are with respect to GND.
Recommended Operating Conditions
MIN
2.7
25
NOM
MAX
5.5
UNIT
V
°
C
Supply voltage, V
DD
Operating free-air temperature range, T
A
5
70
Electrical Characteristics at V
DD
= 5 V, T
A
= 25
°
C (unless otherwise noted)
PARAMETER
TEST CONDITIONS
I
OH
=
4 mA
I
OL
= 4 mA
MIN
TYP
4.5
0.25
MAX
UNIT
V
V
mA
kHz
%/V
V
OH
V
OL
I
DD
High-level output voltage
Low-level output voltage
Supply current
Full-scale frequency
Supply-voltage sensitivity
Full-scale frequency is the maximum operating frequency of the device without saturation.
4
0.4
2
3
500
k
SVS
V
DD
= 5 V
±
10%
±
0.5
Operating Characteristics at V
DD
= 5 V, T
A
= 25
°
C,
λ
p = 940 nm
PARAMETER
TEST CONDITIONS
E
e
= 40
μ
W/cm
2
E
e
= 0
μ
W/cm
2
MIN
10
TYP
20
MAX
UNIT
kHz
f
O
f
D
Output frequency
30
Dark frequency
0.4
10
Hz
R
e
Irradiance responsivity
0.5
kHz/(
μ
W/
cm
2
)
%F.S.
%F.S.
Nonlinearity
§
f
O
= 0 kHz to 10 kHz
f
O
= 0 kHz to 100 kHz
±
0.1%
±
0.2%
Step response to full-scale step input
1 pulse of new
frequency plus 1
μ
s
§
Nonlinearity is defined as the deviation of f
O
from a straight line between zero and full scale, expressed as a percent of full scale.