TSL250R, TSL251R, TSL252R
LIGHT-TO-VOLTAGE OPTICAL SENSORS
TAOS028H
SEPTEMBER 2007
2
Copyright 2007, TAOS Inc.
The
LUMENOLOGY
Company
www.taosinc.com
Terminal Functions
TERMINAL
NAME
GND
OUT
V
DD
DESCRIPTION
NO.
1
3
2
Ground (substrate). All voltages are referenced to GND.
Output voltage
Supply voltage
Absolute Maximum Ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, V
DD
(see Note 1)
Output current, I
O
Duration of short-circuit current at (or below) 25
°
C (see Note 2)
Operating free-air temperature range, T
A
Storage temperature range, T
stg
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds (S Package)
Reflow solder, in accordance with J-STD-020C or J-STD-020D (SM Package)
6 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
±
10 mA
5 s
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
25
°
C to 85
°
C
25
°
C to 85
°
C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
260
°
C
260
°
C
. . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES:
1. All voltages are with respect to GND.
2. Output may be shorted to supply.
Recommended Operating Conditions
MIN
2.7
NOM
MAX
5.5
UNIT
V
°
C
Supply voltage, V
DD
Operating free-air temperature, T
A
0
70