4-83
Absolute Maximum Ratings
For ratings of individual members of a series, see Device Ratings and Specifications chart
CP SERIES
UNITS
Continuous:
Steady State Applied Voltage:
AC Voltage Range (V
DC Voltage Range (V
M(AC)RMS
M(DC)
) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6 to 150
8 to 150
V
V
Transient:
Peak Pulse Current (I
For 8/20
μ
Single Pulse Energy Range
For 10/1000
μ
TM
)
s Current Wave (See Figure 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
s Current Wave (W
TM
) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
250 to 500
1.5 to 5
A
J
Operating Ambient Temperature Range (T
A
). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
-55 to 125
o
C
Storage Temperature Range (T
STG
) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
-55 to 150
o
C
o
Temperature Coefficient (
α
V) of Clamping Voltage (V
C
) at Specified Test Current . . . . . . . . . . . . . . . . . .
<0.01
%/
C
CAUTION: Stresses above those listed in “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress only rating and operation of the
device at these or any other conditions above those indicated in the operational sections of this specification is not implied.
Device Ratings and Specifications
PART
MODEL
NUMBER
PART
MAXIMUM RATINGS (125
o
C)
SPECIFICATIONS (25
o
C)
VARISTOR VOLTAGE AT
1mA DC TEST CURRENT
MAX. CLAMPING
VOLTAGE V
TEST CURRENT
(8/20
C
AT
μ
s)
CAPACI-
TANCE AT
f = 1MHz
V
RMS
V
DC
ENERGY
(10/1000
μ
s)
PEAK
CURRENT
(8/20
μ
s)
V
M(AC)
V
M(DC)
W
TM
I
TM
MIN
V
N(DC)
MAX
V
C
I
P
MIN
MAX
(V)
(V)
(J)
(A)
(V)
(V)
(V)
(V)
(A)
(pF)
(pF)
V8CP22
19.5
34.0
10
1600
2950
V14CP22
22B
10.0
14.0
1.5
250
18.5
22.0
25.5
42.0
10
1600
2950
V31CP22
22B
25.0
31.0
1.5
250
35.0
39.0
48.0
85.0
5
450
1950
V38CP22
22B
30.0
38.0
1.5
250
42.0
47.0
58.0
100.0
5
450
1950
V130CP22
228.0
375.0
5
150
350
V150CP22
22A
150.0
150.0
2.4
300
212.0
240.0
268.0
430.0
5
100
300
V31CP20
20B
25.0
31.0
2.0
300
35.0
39.0
48.0
85.0
10
700
2200
V38CP20
20B
30.0
38.0
2.0
300
42.0
47.0
58.0
100.0
10
650
1950
V130CP20
20A
130.0
130.0
3.0
400
184.0
200.0
228.0
375.0
10
150
400
V150CP20
20A
150.0
150.0
3.0
400
212.0
240.0
268.0
430.0
10
100
350
V38CP16
16A
30.0
38.0
3.0
350
42.0
47.0
58.0
100.0
20
1000
2750
V130CP16
16A
130.0
130.0
5.0
500
184.0
200.0
228.0
375.0
20
250
700
V150CP16
16A
150.0
150.0
5.0
500
212.0
240.0
268.0
430.0
20
200
650