2 of 3
VCO-118S/STC
DS100426
7628 Thorndike Road, Greensboro, NC 27409-9421 · For sales or technical
support, contact RFMD at (+1) 336-678-5570 or sales-support@rfmd.com.
Absolute Maximum Ratings
Parameter
Supply Voltage (V
CC
)
V
TUNE
Storage Temperature
Operating Temperature
ESD JESD22 - A114 Human Body
Model (HBM)
Rating
17
Unit
V
0 to 22
V
-65 to 150
-55 to 100
°C
°C
V
Parameter
Specification
Typ.
Unit
Condition
Min.
Max.
Frequency
Frequency Range
Tuning Voltage
250
500
MHz
100% Production Tested
250MHz
0
1.3
V
DC
V
DC
100% Production Tested
500MHz
17.6
20
100% Production Tested
Tuning Sensitivity
250MHz
312.5MHz
375MHz
437.5MHz
500MHz
11.9
12.6
14.9
13.1
6.2
10
15.8
16.8
19.8
17.4
8.3
13
19.8
21
24.8
21.8
10.8
16
MHz/V
MHz/V
MHz/V
MHz/V
MHz/V
dBm
100% Production Tested
100% Production Tested
100% Production Tested
100% Production Tested
100% Production Tested
100% Production Tested
Output Power
Output Phase Noise
10kHz
100kHz
1000kHz
-100
-123
-148
15
14.5
-94
-117
-142
15.25
16
dBc/Hz
dBc/Hz
dBc/Hz
V
mA
100% Production Tested
100% Production Tested
100% Production Tested
100% Production Tested
100% Production Tested
100% Production Tested
100% Production Tested
100% Production Tested
Power Supply
Supply Current
Harmonic Suppression
14.75
2nd Harmonic
3rd Harmonic
-12
-12
-10
-10
-80
3
13
dBc
dBc
dBc
Spurious (Non-Harmonic)
Frequency Pushing
Frequency Pulling
Output Impedance
3dB Modulation Bandwidth
1
10
50
MHz p-p
MHz p-p
kHz
k
14.75V to 15.25V
12dB RL
5000
10000
Z
G
=50
Tune Port Impedance (DC)
50
Caution! ESD sensitive device.
Exceeding any one or a combination of the Absolute Maximum Rating conditions may
RoHS status based on EUDirective2002/95/EC (at time of this document revision).
The information in this publication is believed to be accurate and reliable. However, no