14
Standard Specifications
Voltage Class
115V Class
40W
270 (0.60)
350 (0.77)
25/40
106/152
0.28/0.4
Two times proportion to
Input Voltage
230V Class
40W
260 (0.57)
340 (0.75)
25/40
106/152
0.28/0.4
Proportional to Input
Voltage
1.00 to 120.00 Hz
Single phase
100 to 120 VAC
50/60 Hz
Voltage:
±
10%, Frequency:
±
5%
1.1A 1.5A 2.2A 3.0A 0.5A 0.7A 1.0A 1.4A
SVPWM (Space Vector Pulse Width Modulation,
carrier frequency 10kHz)
High/Low, Switching
150% of rated current for 1 minute
0.05 to 30.0 seconds
Torque Boots: 0 or 8%
Potentiometer
RUN/STOP, FORWARD/REVERSE
Ext. Terminal RUN/STOP, FORWARD/REVERSE, RS-485
Panel
Fault Indication (LED Flash)
Model Number VFD- L A/B
Weight g (lb) A (standard)
Weight g (lb) B (build-in EMI filter)
Max. Applicable Motor Output (W)
Rated Output Capacity (VA)
Rated Output Current (A)
001
001
440 (0.97)
525 (1.16)
60/100
212/303
0.56/0.8
430 (0.95)
510 (1.12)
60/100
212/303
0.56/0.8
Maximum Output Voltage (V)
O
Rated Frequency (Hz)
Rated Voltage/Frequency
Single phase
200 to 240 VAC 50/60Hz
Voltage/Freq. Tolerance
Input Current (A)
I
Control Systems
Torque Setting
Overload Endurance
Accel/Decel Time
Torque Promotion
Frequency Setting
Operation Setting
Signal
C
C
Panel
O
C
Output Indiction
Ext. Terminal Fault Indication (Open Collector)
Self-testing, Over Voltage, Over Current, Under
Voltage, Overload, Overheating, Thermal.
Natural air-cooling
Altitude 1,000m or lower, keep from corrosive
gasses, liquid and dust
2
Ambient Temperature
-10
o
C to 40
o
C (Non-Condensing and not frozen)
Storage Temperature
-20
o
C to 60
o
C
Ambient Humidity
Below 90% RH (non-condensing)
9.80665m/s
2
(1G) less than 20Hz, 5.88m/s
2
(0.6G) at 20 to 50Hz
Protection
Cooling
Installation Location
Pollution Degree
E
Vibration