OUTPUT 1
OUTPUT 2
OUTPUT 3
PARAMETER
CONDITIONS
Min
Nom
Max
Min
Nom
Max
Min
Nom
Max
UNITS
Output Power
Total Combined O/P Power =
100 Watts Maximum
50
100
25
50
25
50
W
Set Point Voltage
I
O Nom
3.3
15.85
V
Output Current, I
OUT
0.5
15
30.0
0
1.66
3.33
0
1.66
3.33
A
Output Ripple, p-p
DC to 20MHz*
100
200
125
500
125
500
mV
Output Adjust Range
*
3.15
3.80
Dependent on V1
V
Output Temperature Drift
.02
.05
.02
.05
.02
.05
%/°C
Line Regulation
V
IN, Min
V
IN
V
IN, Max
I
O = IO, Nom
0.05
0.10
1.0
2.0
1.0
2.0
%
Load Regulation
Min Load to Rated Load
0.50
1.0
%
Current Limit Inception
Other Outputs Min Load
38
5.0
A
Short-Circuit Current
30
38
4.0
5.0
4.0
5.0
A
Transient Response
50 to 100% Load Step
Peak Deviation
150
250
mV
Settling Time
V
OUT, 1% of VOUT, Nom
35
50
Sec
Overvoltage Limit
4.2
5.0
V
Efciency
I
OUT1=15A, (IOUT2+IOUT3) = 3.4A
85
86
%
F.L. V
IN=Nominal
See Regulation Curves
VKP100MT315C OUTPUT SPECIFICATIONS Specications are at T
CASE = +40°C nominal input voltage unless otherwise specied.
OUTPUT 1
OUTPUT 2
OUTPUT 3
PARAMETER
CONDITIONS
Min
Nom
Max
Min
Nom
Max
Min
Nom
Max
UNITS
Output Power
Total Combined O/P Power =
100 Watts Combined
50
100
25
50
25
50
W
Set Point Voltage
I
O Nom
5.1
12
V
Output Current, I
OUT
0.5
10
20
0
2.1
4.2
0
2.1
4.2
A
Output Ripple, p-p
DC to 20MHz*
100
150
500
150
500
mV
Output Adjust Range
*
4.75
5.50
Dependent on V1
V
Output Temperature Drift
.02
.05
.02
.05
.02
.05
%/°C
Line Regulation
V
IN, Min
V
IN
V
IN, Max
I
O = IO, Nom
0.05
0.10
1.0
2.0
1.0
2.0
%
Load Regulation
Min Load to Rated Load
0.50
1.0
%
Current Limit Inception
Other Outputs Min Load
26.0
6.0
A
Short-Circuit Current
20.0
26.0
5.0
6.0
5.0
6.0
A
Transient Response
50 to 100% Load Step
Peak Deviation
200
300
mV
Settling Time
V
OUT, 1% of VOUT, Nom
35
50
Sec
Overvoltage Limit
6.0
7.0
V
Efciency
I
OUT1=10A, (IOUT2+IOUT3) = 4.2A
86
87
%
F.L. V
IN=Nominal
See Regulation Curves
VKP100MT512C OUTPUT SPECIFICATIONS Specications are at T
CASE = +40°C
nominal input voltage unless otherwise specied.
OUTPUT 1
OUTPUT 2
OUTPUT 3
PARAMETER
CONDITIONS
Min
Nom
Max
Min
Nom
Max
Min
Nom
Max
UNITS
Output Power
Total Combined O/P Power =
100 Watts Max
50
100
25
50
25
50
W
Set Point Voltage
I
O Nom
5.0
15.3
V
Output Current, I
OUT
0.5
10
20
0
1.66
3.33
0
1.66
3.33
A
Output Ripple, p-p
DC to 20MHz*
100
150
125
500
125
500
mV
Output Adjust Range
*
4.60
5.50
Dependent on V1
V
Output Temperature Drift
.02
.05
.02
.05
.02
.05
%/°C
Line Regulation
V
IN, Min
V
IN
V
IN, Max
I
O = IO, Nom
0.05
1.0
2.0
1.0
2.0
%
Load Regulation
Min Load to Rated Load
0.05
1.0
%
Current Limit Inception
Other Outputs Min Load
26.0
5.0
A
Short-Circuit Current
20.0
26.0
4.0
5.0
4.0
5.0
A
Transient Response
50 to 100% Load Step
Peak Deviation
200
300
mV
Settling Time
V
OUT, 1% of VOUT, Nom
35
50
Sec
Overvoltage Limit
6.0
7.0
V
Efciency
I
OUT1=10A, (IOUT2+IOUT3) = 4.2A
86
87
%
F.L. V
IN=Nominal
VKP100MT515C OUTPUT SPECIFICATIONS Specications are at T
CASE = +40°C nominal input voltage unless otherwise specied.
See Regulation Curves
*See Application Notes available on the web at www.cd4power.com
VKP100MTC.B01 Page 3 of 6
Technical enquiries - email: sales@murata-ps.com, tel: +1 508 339 3000
www.murata-ps.com
VKP100MTC Series
100 Watt, Dual/Triple Output, Half Brick DC/DC Converter