X25080
8
*COMMENT
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
This is a stress rating only and the functional operation of
the device at these or any other conditions above those
listed in the operational sections of this specification is
not implied. Exposure to absolute maximum rating con-
ditions for extended periods may affect device reliability.
ABSOLUTE MAXIMUM RATINGS*
Temperature under Bias .................. –65
°
C to +135
°
C
Storage Temperature ....................... –65
°
C to +150
°
C
Voltage on any Pin with Respect to V
SS.........
–1V to +7V
D.C. Output Current .............................................5mA
Lead Temperature
(Soldering, 10 seconds).............................. 300
°
C
RECOMMENDED OPERATING CONDITIONS
Temp
Commercial
Industrial
Military
Min.
0
°
C
–40
°
C
–55
°
C
Max.
+70
°
C
+85
°
C
+125
°
C
3090 PGM T06.1
Supply Voltage
X25080
X25080-2.7
Limits
5V
±
10%
2.7V to 5.5V
3090 PGM T07.1
POWER-UP TIMING
Symbol
t
PUR(3)
t
PUW(3)
Parameter
Min.
Max.
1
Units
ms
Power-up to Read Operation
Power-up to Write Operation
5
ms
3090 PGM T09
D.C. OPERATING CHARACTERISTICS
(Over the recommended operating conditions unless otherwise specified.)
Limits
Symbol
I
CC
Parameter
V
CC
Supply Current (Active)
Min.
Max.
5
Units
mA
Test Conditions
SCK = V
CC
x 0.1/V
CC
x 0.9 @ 2MHz,
SO = Open,
CS
=
V
SS
CS
= V
CC
,
V
IN
=
V
SS
or V
CC
V
IN
=
V
SS
to V
CC
V
OUT
=
V
SS
to V
CC
I
SB
I
LI
I
LO
V
IL(1)
V
IH(1)
V
OL1
V
OH1
V
OL2
V
OH2
V
CC
Supply Current (Standby)
Input Leakage Current
Output Leakage Current
Input LOW Voltage
Input HIGH Voltage
Output LOW Voltage
Output HIGH Voltage
Output LOW Voltage
Output HIGH Voltage
1
10
10
μ
A
μ
A
μ
A
V
V
V
V
V
V
–1
V
CC
x 0.3
V
CC
+ 0.5
0.4
V
CC
x 0.7
V
CC
= 5V, I
OL
= 3mA
V
CC
= 5V, I
OH
= -1.6mA
V
CC
= 3V, I
OL
= 1.5mA
V
CC
= 3V, I
OH
= -0.4mA
V
CC
– 0.8
0.4
V
CC
– 0.3
3090 PGM T08.3
CAPACITANCE
T
A
= +25
°
C, f = 1MHz, V
CC
= 5V.
Symbol
C
OUT(2)
Output Capacitance (SO)
C
IN(2)
Input Capacitance (SCK, SI,
CS
,
WP
,
HOLD
)
Notes:
(1) V
IL
min. and V
IH
max. are for reference only and are not tested.
(2) This parameter is periodically sampled and not 100% tested.
(3) t
PUR
and t
PUW
are the delays required from the time V
CC
is stable until the specified operation can be initiated. These parameters
are periodically sampled and not 100% tested.
Test
Max.
8
6
Units
pF
pF
Conditions
V
OUT
= 0V
V
IN
= 0V
3090 PGM T10.1