X25097
8
ABSOLUTE MAXIMUM RATINGS*
Temperature under Bias...................–65
Storage Temperature .......................–65
Voltage on any Pin with
Respect to V
SS
................................... –1V to +7V
D.C. Output Current..............................................5mA
Lead Temperature
(Soldering, 10 seconds).............................. 300
°
°
C to +135
C to +150
°
°
C
C
°
C
*COMMENT
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
This is a stress rating only and the functional operation of
the device at these or any other conditions above those
indicated in the operational sections of this specification
is not implied. Exposure to absolute maximum rating con-
ditions for extended periods may affect device reliability.
7038 FRM T05
Supply Voltage
X25097
X25097-2.7
X25097-1.8
Limits
4.5V to 5.5V
2.7V to 5.5V
1.8V to 3.6V
D.C. OPERATING CHARACTERISTICS
(Over the recommended operating conditions, unless otherwise specified.)
7038 FRM T06
POWER-UP TIMING
7038 FRM T07
Notes:
(1) V
(2) t
IL
Min. and V
and t
are periodically sampled and not 100% tested.
IH
are the delays required from the time V
Max. are for reference only and are not 100% tested.
PUR
PUW
CC
is stable until the specified operation can be initiated. These parameters
Limits
Symbol
Parameter
Supply Current (Write)
Min.
Max.
3
Units
mA
Test Conditions
x 0.1/V
CC
SS
x 0.1/V
CC
SS
, V
IN
=
V
SS
to V
CC
to V
CC
I
CC1
V
CC
SCK = V
SO = Open, CS =
V
CC
x 0.9 @ 5MHz,
I
CC2
V
CC
Supply Current (Read)
400
μ
A
SCK = V
SO = Open, CS =
V
CS = V
CC
V
IN
=
V
SS
V
OUT
=
V
SS
CC
x 0.9 @ 5MHz,
I
I
I
V
V
V
V
OL2
V
OL3
V
OH1
V
OH2
V
OH3
SB
V
Input Leakage Current
Output Leakage Current
Input LOW Voltage
Input HIGH Voltage
Output LOW Voltage
Output LOW Voltage
Output LOW Voltage
Output HIGH Voltage
Output HIGH Voltage
Output HIGH Voltage
CC
Supply Current (Standby)
1
μ
μ
μ
V
V
V
V
V
V
V
V
A
A
A
or V
CC
LI
10
10
x 0.3
+ 0.5
0.4
0.4
0.4
LO
IL
(1)
–0.5
x 0.7
V
V
CC
IH
(1)
V
CC
CC
OL1
V
CC
> 3.3V, I
OL
= 2.1mA
2V < V
CC
≤
3.3V, I
OL
= 1mA
V
CC
≤
2V, I
OL
= 0.5mA
V
CC
> 3.3V, I
OH
= -1.0mA
2V < V
CC
≤
3.3V, I
OH
= -0.4mA
V
CC
≤
2V, I
OH
= -0.25mA
V
CC
– 0.8
V
CC
– 0.4
V
CC
– 0.2
Symbol
t
PUR
(2)
t
PUW
(2)
Parameter
Min.
Max.
1
5
Units
Power-up to Read Operation
Power-up to Write Operation
ms
ms
RECOMMENDED OPERATING CONDITIONS
7038 FRM T04
Temperature
Commercial
Industrial
Min.
Max.
0
°
C
–40
°
C
+70
°
C
+85
°
C