X2816C
5
*COMMENT
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
This is a stress rating only and the functional operation of
the device at these or any other conditions above those
indicated in the operational sections of this specification is
not implied. Exposure to absolute maximum rating condi-
tions for extended periods may affect device reliability.
ABSOLUTE MAXIMUM RATINGS*
Temperature under Bias
X2816C....................................... –10
°
C to +85
°
C
X2816CI..................................... –65
°
C to +135
°
C
Storage Temperature ....................... –65
°
C to +150
°
C
Voltage on any Pin with
Respect to V
SS
.................................. –1V to +7V
D.C. Output Current .............................................5mA
Lead Temperature (Soldering, 10 seconds)...... 300
°
C
RECOMMENDED OPERATING CONDITIONS
Temperature
Min.
0
°
C
–40
°
C
Max.
+70
°
C
+85
°
C
3852 PGM T02.2
Commercial
Industrial
Supply Voltage
Limits
5V
±
10%
X2816C
3852 PGM T03.1
D.C. OPERATING CHARACTERISTICS
(Over recommended operating conditions unless otherwise specified.)
Limits
Typ.
(1)
Symbol
Parameter
Min.
Max.
Units
Test Conditions
I
CC
V
CC
Current (Active)
70
110
mA
CE
=
OE
= V
IL
All I/O’s = Open
Other Inputs = V
CC
CE
= V
IH
,
OE
= V
IL
All I/O’s = Open
Other Inputs = V
CC
V
IN
= V
SS
to V
CC
V
OUT
= V
SS
to V
CC
,
CE
= V
IH
I
SB1
V
CC
Current (Standby)
35
50
mA
I
LI
I
LO
V
lL(2)
V
IH(2)
V
OL
V
OH
Input Leakage Current
Output Leakage Current
Input LOW Voltage
Input HIGH Voltage
Output LOW Voltage
Output HIGH Voltage
10
10
0.8
μ
A
μ
A
V
V
V
V
–1
2
V
CC
+1
0.4
I
OL
= 2.1mA
I
OH
= –400
μ
A
2.4
3852 PGM T02.2
Notes:
(1) Typical values are for T
A
= 25
°
C and nominal supply voltage and are not tested.