X46402
Preliminary Information
16
D.C. OPERATING CHARACTERISTICS
(Over the recommended operating conditions unless otherwise specified.)
Symbol
Parameter
Limits
Units
Test Conditions
Min.
Max.
I
CC1
V
CC
Supply Current
(Read)
1
mA
f
SCL
= 1MHz,
RESET = V2FAIL = V
CC
w/ pull up resistor
V
2MON
= V
CC
f
SCL
= 1MHz,
RESET = V2FAIL = V
CC
w/ pull up resistor
RST = V
SS
V
IL
= V
CC
x 0.1, V
IH
= V
CC
x 0.9
f
SCL
= 1MHz, f
SDA
= 400 KHz
V
SDA
= V
SCL
= V
2MON
= V
CC
Other = GND or V
CC
–0.3V
V
IN
= V
SS
to V
CC
V
OUT
= V
SS
to V
CC
V
CC
= 3.0V
V
CC
= 3.0V
V
CC
= 3.0V
V
CC
= 3.0V
I
OL
= 3mA
I
CC2(3)
V
CC
Supply Current
(Write)
3
mA
I
SB1(1)
V
CC
Supply Current
(Standby)
50
μA
I
SB2(1)
V
CC
Supply Current
(Standby)
1
μA
I
LI
I
LO
V
IL1(2)
V
IH1(2)
V
IL2(2)
V
IH2(2)
V
OL
Input Leakage Current
Output Leakage Current
10
10
μA
μA
Input LOW Voltage
–0.5
V
CC
x 0.3
V
Input HIGH Voltage
V
CC
x 0.7 V
CC
+ 0.5
V
Input LOW Voltage
–0.5
V
CC
x 0.1
V
Input HIGH Voltage
V
CC
x 0.9 V
CC
+ 0.5
V
Output LOW Voltage
0.4
V
An easier way to determine that the password has been
changed correctly is to read the ACK bit following the
second writing of the new password. If the device returns
an ACK, the password is good. A No ACK indicates
something went wrong. If there was an error, the pass-
word remains unchanged.
There is no way to read any of the passwords.
ABSOLUTE MAXIMUM RATINGS*
Temperature under Bias . . . . . . . . . . . .–65°C to +135°C
Storage Temperature . . . . . . . . . . . . . . .–65°C to +150°C
Voltage on any Pin with respect to V
SS
. . . . .–1V to +7V
D.C. Output Current . . . . . . . . . . . . . . . . . . . . . . . . . .5mA
Lead Temperature (Soldering, 10 seconds) . . . . . .300°C
*COMMENT
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
This is a stress rating only and the functional operation of
the device at these or any other conditions above those
listed in the operational sections of this specification is
not implied. Exposure to absolute maximum rating condi-
tions for extended periods may affect device reliability.
RECOMMENDED OPERATING CONDITIONS
Temp
Commercial
Extended
Min.
0°C
–20°C
Max.
+70°C
+85°C
Device
X46402
Supply Voltage Limits
2.5V to 3.7V