X9241
9
Notes:
(1) Absolute Linearity is utilized to determine actual wiper voltage versus expected voltage as determined by wiper
position when used as a potentiometer.
(2) Relative Linearity is utilized to determine the actual change in voltage between two successive tap positions when used as a
potentiometer. It is a measure of the error in step size.
(3) MI = RTOT/63 or (V
H
– V
L
)/63, single pot
(4) Max. = all four arrays cascaded together, Typical = individual array resolutions.
ABSOLUTE MAXIMUM RATINGS*
Temperature under Bias .................. –65
°
C to +135
°
C
Storage Temperature ....................... –65
°
C to +150
°
C
Voltage on SCK, SCL or any Address Input
with Respect to V
SS...................................
–1V to +7V
Voltage on any V
H
or V
L
Referenced to V
SS.........
±
8V
V = |V
H
–V
L
|.........................................................16V
Lead Temperature (Soldering, 10 seconds)...... 300
°
C
RECOMMENDED OPERATING CONDITIONS
*COMMENT
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
This is a stress rating only and the functional operation of
the device at these or any other conditions above those
indicated in the operational sections of this specification is
not implied. Exposure to absolute maximum rating condi-
tions for extended periods may affect device reliability.
Temperature
Min.
0
°
C
–40
°
C
–55
°
C
Max.
+70
°
C
+85
°
C
+125
°
C
3864 PGM T03
Commercial
Industrial
Military
Supply Voltage
Limits
5V
±
10%
X9241
3864 PGM T04.1
ANALOG CHARACTERISTICS
(Over recommended operating conditions unless otherwise stated.)
Limits
Symbol
R
TOTAL
Parameter
Min.
–20
Typ.
Max.
+20
50
+1
100
+5
Units
%
mW
mA
V
Test Conditions
End to End Resistance
Power Rating
Wiper Current
Wiper Resistance
Voltage on any V
H
or
or V
L
Pin
Noise
Resolution
(4)
Absolute Linearity
(1)
Relative Linearity
(2)
Temperature Coefficient
25
°
C, each pot
I
W
R
W
V
TERM
–1
40
Wiper Current =
±
1mA
–5
≤
120
1.6
dB/
Ref: 1V
0.4
+1
+0.2
%
–1
–0.2
MI
(3)
MI
(3)
ppm/
°
C
V
w(n)(actual)
– V
w(n)(expected)
V
w(n + 1)
– [V
w(n) + MI
]
±
300
3864 PGM T05.2
D.C. OPERATING CHARACTERISTICS
(Over recommended operating conditions unless otherwise stated.)
Limits
Symbol
l
CC
Parameter
Min.
Typ.
Max.
3
Units
mA
Test Conditions
f
SCL
= 100KHz, SDA = Open,
Other Inputs = V
SS
SCL=SDA=V
CC
, Addr. = V
SS
V
IN
= V
SS
to V
CC
V
OUT
= V
SS
to V
CC
Supply Current (Active)
I
SB
I
LI
I
LO
V
IH
V
IL
V
OL
V
CC
Current (Standby)
Input Leakage Current
Output Leakage Current
Input HIGH Voltage
Input LOW Voltage
Output LOW Voltage
200
500
10
10
μ
A
μ
A
μ
A
V
V
V
2
–1
V
CC
+ 1
0.8
0.4
I
OL
= 3mA
3864 PGM T06.3