![](http://datasheet.mmic.net.cn/Intersil/X9259UV24IT2_datasheet_99892/X9259UV24IT2_13.png)
13
FN8169.5
April 13, 2007
NOTES:
1. Absolute linearity is utilized to determine actual wiper voltage versus expected voltage as determined by wiper position when used as a
potentiometer.
2. Relative linearity is utilized to determine the actual change in voltage between two successive tap positions when used as a
potentiometer. It is a measure of the error in step size.
3. MI = RTOT / 255 or (RH – RL) / 255, single pot
4. During power up VCC > VH, VL, and VW.
5. n = 0, 1, 2, …,255; m =0, 1, 2, …, 254.
Absolute Maximum Ratings
Recommended Operating Conditions
Temperature under bias . . . . . . . . . . . . . . . . . . . . . .-65
°C to +135°C
Storage temperature . . . . . . . . . . . . . . . . . . . . . . . .-65
°C to +150°C
Voltage on SCL, SDA, any address input, VCC
with respect to VSS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -1V to +7V
ΔV = | (V
H–VL) | . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5V
Lead temperature (soldering, 10 seconds) . . . . . . . . . . . . . . . 300
°C
IW (10 seconds) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±6mA
Temperature (Commercial) . . . . . . . . . . . . . . . . . . . . . 0°C to +70°C
Temperature (Industrial). . . . . . . . . . . . . . . . . . . . . . . -40°C to +85°C
Supply Voltage (VCC) (Note 4) Limits
X9259. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5V ± 10%
X9259-2.7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.7V to 5.5V
Wiper current ...........................................................................±3mA
Power rating (each pot) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50mW
CAUTION: Stresses above those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress rating only; the functional
operation of the device (at these or any other conditions above those listed in the operational sections of this specification) is not implied. Exposure to absolute maximum
rating conditions for extended periods may affect device reliability.
Analog Specifications
Over recommended industrial (2.7V) operating conditions unless otherwise stated.
SYMBOL
PARAMETER
TEST CONDITIONS
LIMITS
MIN
TYP
MAX
UNITS
RTOTAL
End to End Resistance
T version
100
k
Ω
RTOTAL
End to End Resistance
U version
50
k
Ω
End to End Resistance Tolerance
±20
%
RW
Wiper Resistance
IW =
@ VCC = 3V
300
Ω
IW =
@ VCC = 5V
220
Ω
VTERM
Voltage on any RH or RL Pin
VSS = 0V
VSS
VCC
V
Ref: 1V
-120
dB
/√Hz
Resolution
0.4
%
Absolute Linearity (Note
1)Rw(n)(actual) - Rw(n)(expected) (Note 5) -1
+1
Relative Linearity (Note
2)Rw(n + 1) - [Rw(n) + MI] (Note 5) -0.6
+0.6
Temperature Coefficient of RTOTAL
±300
ppm/
°C
Ratiometric Temp. Coefficient (Note
6)±20
ppm/°C
CH/CL/CW
Potentiometer Capacitances (Note
6)See Macro model
10/10/25
pF
V(VCC)
RTOTAL
V(VCC)
RTOTAL
X9259