D.C. OPERATING CHARACTERISTICS
(Over the recommended operating conditions unless otherwise specified.)
ENDURANCE AND DATA RETENTION
CAPACITANCE
POWER-UP TIMING
POWER UP REQUIREMENTS
(Power up sequencing can affect correct recall of the wiper registers)
The preferred power-on sequence is as follows: First V
CC
, then V+ and V–, and then the potentiometer pins, R
H
,
R
L
, and R
W
. Voltage should not be applied to the potentiometer pins before V+ or V– is applied. The V
CC
ramp rate
specification should be met, and any glitches or slope changes in the V
CC
line should be held to <100mV if
possible. If V
CC
powers down, it should be held below 0.1V for more than 1 second before powering up again in
order for proper wiper register recall. Also, V
CC
should not reverse polarity by more than 0.5V. Recall of wiper
position will not be complete until V
CC
, V+ and V– reach their final value.
Notes:
(5) This parameter is periodically sampled and not 100% tested.
(6) t
PUR
and t
PUW
are the delays required from the time the third (last) power supply (V
CC
, V+ or V-) is stable until the specific
instruction can be issued. These parameters are periodically sampled and not 100% tested.
Symbol
I
CC1
Parameter
Limits
Test Conditions
f
SCK
= 2MHz, SO = Open,
Other Inputs = V
SS
f
SCK
= 2MHz, SO = Open,
Other Inputs = V
SS
SCK = SI = V
SS
, Addr. = V
SS
V
IN
= V
SS
to V
CC
V
OUT
= V
SS
to V
CC
Min.
Typ.
Max.
400
Units
μA
V
CC
Supply Current (Active)
I
CC2
V
CC
Supply Current
(Non-volatile Write)
V
CC
Current (Standby)
Input Leakage Current
Output Leakage Current
Input HIGH Voltage
Input LOW Voltage
Output LOW Voltage
1
mA
I
SB
I
LI
I
LO
V
IH
V
IL
V
OL
1
10
10
μ
A
μ
A
μ
A
V
V
V
V
CC
x 0.7
–0.5
V
CC
+ 0.5
V
CC
x 0.1
0.4
I
OL
= 3mA
Parameter
Minimum Endurance
Data Retention
Min.
100,000
100
Units
Data Changes per Bit per Register
Years
Symbol
C
OUT
(5)
C
IN
(5)
Test
Max.
8
6
Units
pF
pF
Test Conditions
V
OUT
= 0V
V
IN
= 0V
Output Capacitance (SO)
Input Capacitance (A0, SI, and SCK)
Symbol
t
PUR
(6)
t
PUW
(6)
t
R
V
CC
Parameter
Max.
1
5
0.2
Max.
1
5
50
Units
ms
ms
V/msec
Power-up to Initiation of Read Operation
Power-up to Initiation of Write Operation
V
CC
Power up Ramp
相關(guān)PDF資料
PDF描述
X9420YPI Single Digitally Controlled (XDCP) Potentiometer
X9420YPM Single Digitally Controlled (XDCP) Potentiometer
X9420YS Single Digitally Controlled (XDCP) Potentiometer
X9420YSI Single Digitally Controlled (XDCP) Potentiometer
X9420YSM Single Digitally Controlled (XDCP) Potentiometer
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
X9420YP-2.7 制造商:XICOR 制造商全稱:Xicor Inc. 功能描述:Single Digitally Controlled (XDCP) Potentiometer
X9420YPI 制造商:XICOR 制造商全稱:Xicor Inc. 功能描述:Single Digitally Controlled (XDCP) Potentiometer
X9420YPI-2.7 制造商:XICOR 制造商全稱:Xicor Inc. 功能描述:Single Digitally Controlled (XDCP) Potentiometer
X9420YPM 制造商:XICOR 制造商全稱:Xicor Inc. 功能描述:Single Digitally Controlled (XDCP) Potentiometer
X9420YPM-2.7 制造商:XICOR 制造商全稱:Xicor Inc. 功能描述:Single Digitally Controlled (XDCP) Potentiometer