參數(shù)資料
型號(hào): XTR106PA
元件分類: 運(yùn)動(dòng)控制電子
英文描述: A/D Converter (A-D) IC; Resolution (Bits):20; Sample Rate:100SPS; Input Channels Per ADC:1; Input Channel Type:Differential; Data Interface:Serial; Package/Case:8-SOIC; Interface Type:Serial; Leaded Process Compatible:No RoHS Compliant: Yes
中文描述: 的4 - 20mA的電橋激勵(lì)和線性電流變送器
文件頁數(shù): 14/15頁
文件大小: 272K
代理商: XTR106PA
14
XTR106
Most surge protection zener diodes have a diode character-
istic in the forward direction that will conduct excessive
current, possibly damaging receiving-side circuitry if the
loop connections are reversed. If a surge protection diode is
used, a series diode or diode bridge should be used for
protection against reversed connections.
RADIO FREQUENCY INTERFERENCE
The long wire lengths of current loops invite radio fre-
quency interference. RF can be rectified by the sensitive
input circuitry of the XTR106 causing errors. This generally
appears as an unstable output current that varies with the
position of loop supply or input wiring.
If the bridge sensor is remotely located, the interference may
enter at the input terminals. For integrated transmitter as-
semblies with short connection to the sensor, the interfer-
ence more likely comes from the current loop connections.
Bypass capacitors on the input reduce or eliminate this input
interference. Connect these bypass capacitors to the I
RET
terminal as shown in Figure 6. Although the dc voltage at
the I
RET
terminal is not equal to 0V (at the loop supply, V
PS
)
this circuit point can be considered the transmitter’s “ground.”
The 0.01
μ
F capacitor connected between V+ and I
O
may
help minimize output interference.
REVERSE-VOLTAGE PROTECTION
The XTR106’s low compliance rating (7.5V) permits the
use of various voltage protection methods without compro-
mising operating range. Figure 6 shows a diode bridge
circuit which allows normal operation even when the volt-
age connection lines are reversed. The bridge causes a two
diode drop (approximately 1.4V) loss in loop supply volt-
age. This results in a compliance voltage of approximately
9V—satisfactory for most applications. A diode can be
inserted in series with the loop supply voltage and the V+
pin as shown in Figure 8 to protect against reverse output
connection lines with only a 0.7V loss in loop supply
voltage.
OVER-VOLTAGE SURGE PROTECTION
Remote connections to current transmitters can sometimes be
subjected to voltage surges. It is prudent to limit the maximum
surge voltage applied to the XTR106 to as low as practical.
Various zener diode and surge clamping diodes are specially
designed for this purpose. Select a clamp diode with as low a
voltage rating as possible for best protection. For example, a
36V protection diode will assure proper transmitter operation
at normal loop voltages, yet will provide an appropriate level
of protection against voltage surges. Characterization tests on
three production lots showed no damage to the XTR106 with
loop supply voltages up to 65V.
FIGURE 6. Reverse Voltage Operation and Over-Voltage Surge Protection.
V
PS
0.01μF
R
L
D
1(1)
NOTE: (1) Zener Diode 36V: 1N4753A or Motorola
P6KE39A. Use lower voltage zener diodes with loop
power supply voltages less than 30V for increased
protection. See “Over-Voltage Surge Protection.”
Maximum V
must be
less than minimum
voltage rating of zener
diode.
The diode bridge causes
a 1.4V loss in loop supply
voltage.
1N4148
Diodes
14
5
5V
Bridge
Sensor
4
3
2
R
G
XTR106
7
13
V
REF
2.5
6
R
B
R
G
R
G
V
IN
V
IN
+
V+
I
RET
I
O
E
B
9
8
10
Q
1
0.01μF
0.01μF
V
REF
5
+
相關(guān)PDF資料
PDF描述
XTR106U A/D Converter (A-D) IC; Resolution (Bits):16; Sample Rate:60SPS; Input Channels Per ADC:1; Input Channel Type:Differential; Data Interface:Serial, 3/4/5-Wire; Package/Case:; DNL +/-:0.5LSB; Interface Type:Serial RoHS Compliant: No
XTR106UA A/D Converter (A-D) IC; Resolution (Bits):16; ADC Sample Rate:60SPS; Input Channels Per ADC:1; Input Channel Type:Differential Inputs; DNL +/-:0.5LSB; Data Interface:Serial, 3/4/5-Wire; Package/Case:24-SOIC
XTR108 4-20mA, TWO-WIRE TRANSMITTER Smart Programmable with Signal Conditioning
XTR108EA 4-20mA, TWO-WIRE TRANSMITTER Smart Programmable with Signal Conditioning
XTR110L LCC Precision Voltage-to-Current Converter/Transmitter
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
XTR106PA 制造商:Texas Instruments 功能描述:Transceiver IC
XTR106PAG4 功能描述:電流靈敏放大器 4-20mA Crnt Trnsmtr w/Bridger Exc & Lin RoHS:否 制造商:Texas Instruments 通道數(shù)量: 共模抑制比(最小值):110 dB 輸入補(bǔ)償電壓:80 uV 電源電壓-最大:5.5 V 電源電壓-最小:2.7 V 電源電流:350 uA 最大工作溫度:+ 125 C 最小工作溫度:- 40 C 安裝風(fēng)格:SMD/SMT 封裝 / 箱體:VQFN-16 封裝:Reel
XTR106PG4 功能描述:電流靈敏放大器 4-20mA Crnt Trnsmtr w/Bridger Exc & Lin RoHS:否 制造商:Texas Instruments 通道數(shù)量: 共模抑制比(最小值):110 dB 輸入補(bǔ)償電壓:80 uV 電源電壓-最大:5.5 V 電源電壓-最小:2.7 V 電源電流:350 uA 最大工作溫度:+ 125 C 最小工作溫度:- 40 C 安裝風(fēng)格:SMD/SMT 封裝 / 箱體:VQFN-16 封裝:Reel
XTR106U 功能描述:電流靈敏放大器 4-20mA Crnt Trnsmtr w/Bridger Exc & Lin RoHS:否 制造商:Texas Instruments 通道數(shù)量: 共模抑制比(最小值):110 dB 輸入補(bǔ)償電壓:80 uV 電源電壓-最大:5.5 V 電源電壓-最小:2.7 V 電源電流:350 uA 最大工作溫度:+ 125 C 最小工作溫度:- 40 C 安裝風(fēng)格:SMD/SMT 封裝 / 箱體:VQFN-16 封裝:Reel
XTR106U 制造商:Texas Instruments 功能描述:CURRENT LOOP TRANSMITTER SOIC14