(1/2)
003-01 / 20080820 / e9131_zac_me.fm
All specifications are subject to change without notice.
EMC Filters for AC Power Line
For Single-phase, Mid-size Box Cased ZAC-ME Series
FEATURES
The ZAC-ME series employ a highly efficient thermal design,
which ensures high current handling capacity in a compact
package with superior EMC suppression characteristics.
They are highly effective at preventing both the radiation and
penetration of EMC noise. The parts are, therefore, highly
immune to externally generated noise and do not, themselves,
serve as sources of radiated noise.
For the CISPR frequency band, this product provides superior
attenuation for both differential mode and common mode noise
components.
These filters are highly reliable and provide stable attenuation
performance even in harsh environments, where the filters may
be subjected to humidity, vibration, and shock.
Withstand voltage is DC.1770V between the lines and AC.1500V
between line and ground.
Leakage current is maintained at less than 1mA.
It is a product conforming to RoHS directive.
SAFETY STANDARDS
APPLICATIONS
Computers, hard disk drives, electronic exchange devices, NC
control devices, large copiers, etc.
SHAPES AND DIMENSIONS
Dimensions in mm
Case: metal, terminal: stud
ELECTRICAL CHARACTERISTICS
Conformity to RoHS Directive
Part No.
Standard and standard No.
U.S.A.
Canada
UL1283
CSA C22.2 No.8
ZAC2230-ME
E62388
LR76849C
UL
CSA
Part No.
A
B
CDE
F
G
H
I
J
K
ZAC2230-ME
110
170
65
225
90
194
M6
5.5
50
40
210
J
C
G
A
I
H
E
H
B
F
D
K
1
2
3
4
Part No.
ZAC2230-ME
Rated voltage Eac(V)
250
Rated current(A)
30
Test voltage Eac(V)[Between terminal and case]
1500
Insulation resistance(M
)
[DC. 500V, 1min/between terminal and case]
100min.
Leakage current(mA)[250V 60Hz]
1max.
DC resistance(m
)
15max.
Operating temperature range(°C)[Including self-temperature rise]
–25 to +85
With derating over(°C)
55
Temperature rise(°C)
35max.
Attenuation frequency range
(MHz)[+5 to +35°C]
Differential mode
0.15[35dB]0.5[55dB]1[60dB]5[60dB]10[50dB]30[40dB]
Common mode
0.15[35dB]0.5[55dB]1[60dB]5[60dB]10[50dB]30[40dB]
Weight(kg)
1.8
Conformity to RoHS Directive: This means that, in conformity with EU Directive 2002/95/EC, lead, cadmium, mercury, hexavalent chromium, and specific
bromine-based flame retardants, PBB and PBDE, have not been used, except for exempted applications.