CYStech Electronics Corp.
Spec. No. : C326SM
Issued Date : 2003.07.31
Revised Date :
Page No. : 2/3
Electrical Characteristics
(T
L
=30
℃
, unless otherwise noted, V
F
=1.0V Max @I
F
=100mA for all types.)
ZMM55CXXSM series
CYStek Product Specification
Test
Current
Maximum Zener
Impedance
(Note 2)
Z
ZT
at
I
ZT
(
Ω
)
85
85
85
85
85
85
75
60
35
25
10
8
7
7
10
15
20
20
26
30
40
50
55
55
80
80
80
80
80
90
90
110
Maximum Reverse
Leakage Current
I
R
(
μ
A)
50
10
4
2
2
2
1
0.5
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
Device
Nominal
Zener
Voltage
Vz at Iz
T
(V)
(Note1)
2.28-2.56
2.5-2.9
2.8-3.2
3.1-3.5
3.4-3.8
3.7-4.1
4.0-4.6
4.4-5.0
4.8-5.4
5.2-6.0
5.8-6.6
6.4-7.2
7.0-7.9
7.7-8.7
8.5-9.6
9.4-10.6
10.4-11.6
11.4-12.7
12.4-14.1
13.8-15.6
15.3-17.1
16.8-19.1
18.8-21.2
20.8-23.3
22.8-25.6
25.1-28.9
28-32
31-35
34-38
37-41
40-46
44-50
I
ZT
(mA)
Z
ZK
at
I
ZK
=1mA
(
Ω
)
600
600
600
600
600
600
600
600
550
450
200
150
50
50
50
70
70
90
110
110
170
170
220
220
220
220
220
220
220
500
600
700
Typical
Temperature
Coefficient
(%
/
℃
)
Test
Voltage
(V)
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
2.0
3.0
5.0
6.0
7.0
7.5
8.5
9.0
10
11
12
14
15
17
18
20
22
24
27
30
33
36
Maximum
Regulation
Current
I
ZM
(mA)
(Note 3)
ZMM55C2V4
ZMM55C2V7
ZMM55C3V0
ZMM55C3V3
ZMM55C3V6
ZMM55C3V9
ZMM55C4V3
ZMM55C4V7
ZMM55C5V1
ZMM55C5V6
ZMM55C6V2
ZMM55C6V8
ZMM55C7V5
ZMM55C8V2
ZMM55C9V1
ZMM55C10
ZMM55C11
ZMM55C12
ZMM55C13
ZMM55C15
ZMM55C16
ZMM55C18
ZMM55C20
ZMM55C22
ZMM55C24
ZMM55C27
ZMM55C30
ZMM55C33
ZMM55C36
ZMM55C39
ZMM55C43
ZMM55C47
Note: 1.The type numbers listed have zener voltage min/max as shown. Device tolerance of
±
2% are indicated by a “B”
instead of a “C”. Zener voltage is measured with the device junction in thermal equilibrium at the lead temperature
of 30
℃
±1
℃
.
2.Z
ZT
and Z
ZK
are measured by dividing the ac voltage drop across the device by the ac current applied. The specified
limits are for I
Z(ac)
=0.1I
Z(dc)
with the ac frequency = 1k Hz.
3.This data was calculated using nominal voltages. The maximum current handling capability on a worse case basis is
limited by the actual zener voltage at the operating point and the powered derating curve.
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
2.5
2.5
2.5
-0.070
-0.070
-0.070
-0.065
-0.060
-0.050
-0.025
-0.010
+0.015
+0.025
+0.035
+0.045
+0.050
+0.050
+0.060
+0.070
+0.070
+0.070
+0.070
+0.070
+0.070
+0.070
+0.070
+0.070
+0.080
+0.080
+0.080
+0.080
+0.080
+0.080
+0.080
+0.080
150
135
125
115
105
95
90
85
80
70
64
58
53
47
43
40
36
32
29
27
24
21
20
18
16
14
13
12
11
10
9.2
8.5