Pads the snap serves as the ground point. A secon" />
參數(shù)資料
型號(hào): 14240
廠商: Desco
文件頁(yè)數(shù): 6/8頁(yè)
文件大小: 0K
描述: GROUNDING SYSTEM LAMINATE
標(biāo)準(zhǔn)包裝: 1
附件類型: 接地五金件
TB-2091 Page 6 of 8
performing this test on Micastat
Pads the snap serves as
the ground point.
A second type of test is RTT (Resistance, Point to Point).
Here you measure the resistance from one 5 lb. electrode
to another 5 lb. electrode; see electrode test positions A, B,
C, and D in RTT test diagram, Figure 13. This is the test
that is more typically used in the laboratory to determine
Micastat
compliance with electrical specifications.
Both test procedures are outlined in this Technical Bulletin
using the Desco Surface Resistance Test Kit Item No.
19780.
Figure 11. Electrode positions on surface of pad, RTG test.
Resistance To Ground (RTG):
1. Locate the five pound electrode positions, as described
below, to be used on the Micastat
surface in relationship
to the installed ground bolt (or snap on the Micastat
Pad). Use the relative positions shown above.
A -
At least 2" from any surface edge and 3"
from the ground bolt.
B, C & D - The farthest corners from the ground bolt and
2" from any surface edge.
E -
The geometric center of the surface.
2. Disconnect the surface to be tested from its normal
ground connection.
3. Connect one black lead to the meter and the other end
of this lead to the 5 lb. electrode.
Figure 12. Proper connection of leads.
4. Connect the other black lead to the meter and the
groundable point on the mat.
5. Place the electrode at position A on the mat (see the
RTG diagram) and set the meter selector switch to 100V.
6. Push on On/Off button, for the 15 second electrification
period and then record the reading in ohms.
7. Release the On/Off button. Move the electrode to each
of the other four positions on the surface and repeat the
test.
8. Average the results of the five readings to obtain an
average measurement of the resistance of surface to
ground.
Resistance Point to Point (RTT):
Figure 13. Electrode positions on surface of pad, RTT test.
1. Locate the four pair of electrode positions to be used
approximately as shown in the RTT test diagram above.
Position electrodes at least 10 inches apart and not less
than two inches from any edge.
2. Disconnect the surface to be tested from its normal
ground connection.
3. Connect one end of the black lead to the meter connect
the other end of this lead to either one of the electrodes.
It does not matter which lead is connected to which
weighted electrode.
DESCO WEST - 3651 Walnut Avenue, Chino, CA 91710 (909) 627-8178 Fax (909) 627-7449
DESCO EAST - One Colgate Way, Canton, MA 02021-1407 (781) 821-8370 Fax (781) 575-0172 Web Site: http://www.desco.com
2009 DESCO INDUSTRIES, INC.
Employee Owned
相關(guān)PDF資料
PDF描述
OSTHE055040 CONN TERM BLOCK 2.54MM 5POS PCB
OSTHE074041 CONN TERM BLOCK 7POS 2.5MM
3-647031-3 CONN CONTACT 24AWG MTA 100
OSTHA056050 CONN TERM BLOCK 5POS 7.5MM
OSTT5070150 TERM BLOCK 3.50MM 7POS
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
1424004-1 制造商:TE Connectivity 功能描述:INSERTER, TAB - Bulk
14240046 制造商: 功能描述: 制造商:undefined 功能描述:
1424009 功能描述:以太網(wǎng)和電信連接器 VS-08-BU-RJ45/10G-F RoHS:否 制造商:Pulse 產(chǎn)品:Modular Jacks 性能類別: USOC 代碼:RJ45 位置/觸點(diǎn)數(shù)量: 安裝風(fēng)格:Through Hole 端口數(shù)量:1 x 1 型式:Female 屏蔽: 電流額定值: 電壓額定值: 觸點(diǎn)電鍍: 外殼材料:Thermoplastic IP 等級(jí):
1424023 制造商:Phoenix Contact 功能描述:SACC-EC-M12FSB-5CON-PG9/0 5 VA
1424027-2 功能描述:折皺器 LOCATOR TOP RoHS:否 制造商:Hirose Connector 類型: 描述/功能:Cable and Shield Crimper