AC Characteristics for Read Operation
AT27C010 / AT27C010L
-45
-55
-70
-90
-12
-15
Symbol Parameter
Address to
Output Delay
t
CE
(2)
CE to Output Delay
t
OE
(2, 3)
OE to Output Delay
t
DF
(4, 5)
OE or CE High to
Output Float, whichever occurred first
Output Hold from
Address, CE or OE,
whichever occurred first
Notes:
2, 3, 4, 5. - see AC Waveforms for Read Operation.
Condition
CE = OE
= V
IL
OE = V
IL
Min
Max
Min
Max
Min
Max
Min
Max
Min
Max
Min
Max
Units
t
ACC
(3)
45
55
70
90
120
150
ns
45
20
55
25
70
30
90
35
120
35
150
40
ns
ns
CE = V
IL
20
20
25
25
30
35
ns
t
OH
7
7
7
0
0
0
ns
DC and AC Operating Conditions for Read Operation
AT27C010 / AT27C010L
-70
0°C - 70°C
-40°C - 85°C
5V
±
10%
-45
-55
-90
-12
-15
Operating
Temp. (Case)
Com.
Ind.
0°C - 70°C
-40°C - 85°C
5V
±
10%
0°C - 70°C
-40°C - 85°C
5V
±
10%
0°C - 70°C
-40°C - 85°C
5V
±
10%
0°C - 70°C
-40°C - 85°C
5V
±
10%
0°C - 70°C
-40°C - 85°C
5V
±
10%
V
CC
Supply
DC and Operating Characteristics for Read Operation
Symbol
I
LI
I
LO
I
PP1
(
2
)
Parameter
Input Load Current
Output Leakage Current
V
PP
(
1
)
Read/Standby Current
Condition
V
IN
= 0V to V
CC
V
OUT
= 0V to V
CC
V
PP
= V
CC
I
SB1
(CMOS), CE = V
CC
±
0.3V
I
SB2
(TTL), CE = 2.0 to V
CC
+ 0.5V
Min
Max
±
1
±
5
10
Units
μ
A
μ
A
μ
A
μ
A
I
SB
V
CC
(
1
)
Standby Current
100
1
25
35
0.8
mA
mA
mA
V
V
V
V
I
CC
V
CC
Active Current
f = 5 MHz, I
OUT
= 0 mA,
CE = V
IL
AT27C010L
AT27C010
V
IL
V
IH
V
OL
V
OH
Notes: 1. V
CC
must be applied simultaneously or before V
PP
,
and removed simultaneously or after V
PP
.
Input Low Voltage
Input High Voltage
Output Low Voltage
Output High Voltage
-0.6
2.0
V
CC
+ 0.5
0.4
I
OL
= 2.1 mA
I
OH
= -400
μ
A
2.4
2. V
PP
may be connected directly to V
CC
, except during program-
ming. The supply current would then be the sum of I
CC
and I
PP
.
3-156
AT27C010/L