5
www.fairchildsemi.com
7
4
VC
X16
4245
DC Electrical Characteristics (1.65V
VCCA d 1.95V, 3.0V VCCB d 3.6V)
DC Electrical Characteristics (2.3V
VCCA d 2.7V, 3.0V d VCCB d 3.6V)
Symbol
Parameter
Conditions
VCCA
VCCB
Min
Max
Units
(V)
VIHA
HIGH Level
An
1.65–1.95
3.0–3.6
0.65 x VCC
V
VIHB
Input Voltage
Bn, T/R, OE
1.65–1.95
3.0–3.6
2.0
V
VILA
LOW Level
An
1.65–1.95
3.0–3.6
0.35 x VCC
V
VILB
Input Voltage
Bn, T/R, OE
1.65–1.95
3.0–3.6
0.8
V
VOHA
HIGH Level Output Voltage
IOH 100 PA1.65–1.95
3.0–3.6
VCCA–0.2
V
IOH 6 mA
1.65
3.0–3.6
1.25
VOHB
HIGH Level Output Voltage
IOH 100 PA1.65–1.95
3.0–3.6
VCCA–0.2
V
IOH 24 mA
1.65–1.95
3.0
2.2
VOLA
LOW Level Output Voltage
IOL 100 PA1.65–1.95
3.0–3.6
0.2
V
IOL 6 mA
1.65
3.0–3.6
0.3
VOLB
LOW Level Output Voltage
IOL 100 PA1.65–1.95
3.0–3.6
0.2
V
IOL 24 mA
1.65–1.95
3.0
0.55
II
Input Leakage Current @ OE, T/R
0V
d VI d 3.6V
1.65–1.95
3.0–3.6
r5.0
PA
IOZ
3-STATE Output Leakage
0V
d VO d 3.6V
1.65–1.95
3.0–3.6
r10
PA
OE*
VCCB
VI VIH or VIL
IOFF
Power Off Leakage Current
0
d (VI, VO) d 3.6V
0
10
PA
ICCA/ICCB Quiescent Supply Current,
An VCCA or GND
1.65–1.95
3.0–3.6
20
PA
per supply, VCCA/VCCB
Bn, OE, & T/R VCCB or GND
VCCA d An d 3.6V
1.65–1.95
3.0–3.6
r20
PA
VCCB d Bn, OE, T/R d 3.6V
'ICC
Increase in ICC per Input, Bn, T/R, OE
VI VCCB 0.6V
1.65–1.95
3.0–3.6
750
PA
Increase in ICC per Input, An
VI VCCA 0.6V
1.65–1.95
3.0–3.6
750
PA
Symbol
Parameter
Conditions
VCCA
VCCB
Min
Max
Units
(V)
VIHA
HIGH Level Input Voltage An
2.3–2.7
3.0–3.6
1.6
V
VIHB
Bn, T/R, OE
2.3–2.7
3.0–3.6
2.0
V
VILA
LOW Level Input Voltage
An
2.3–2.7
3.0–3.6
0.7
V
VILB
Bn, T/R, OE
2.3–2.7
3.0–3.6
0.8
V
VOHA
HIGH Level Output Voltage
IOH 100 PA2.3–2.7
3.0–3.6
VCCA–0.2
V
IOH 18 mA
2.3
3.0–3.6
1.7
VOHB
HIGH Level Output Voltage
IOH 100 PA2.3–2.7
3.0–3.6
VCCB–0.2
V
IOH 24 mA
2.3–2.7
3.0
2.2
VOLA
LOW Level Output Voltage
IOL 100 PA2.3–2.7
3.0–3.6
0.2
V
IOL 18 mA
2.3
3.0–3.6
0.6
VOLB
LOW Level Output Voltage
IOL 100 PA2.3–2.7
3.0–3.6
0.2
V
IOL 24 mA
2.3–2.7
3.0
0.55
II
Input Leakage Current @ OE, T/R
0V
d VI d 3.6V
2.3–2.7
3.0–3.6
r5.0
PA
IOZ
3-STATE Output Leakage @ An
0V
d VO d 3.6V
2.3–2.7
3.0–3.6
r10
PA
OE
VCCA
VI VIH or VIL
IOFF
Power OFF Leakage Current
0
d (VI, VO) d 3.6V
0
10
PA
ICCA/ICCB
Quiescent Supply Current,
An VCCA or GND
2.3–2.7
3.0–3.6
20
PA
per supply, VCCA/VCCB
Bn, OE, & T/R VCCB or GND
VCCA d An d 3.6V
2.3–2.7
3.0–3.6
r20
PA
VCCB d Bn, OE, T/R d 3.6V
'ICC
Increase in ICC per Input, Bn, T/R, OE
VI VCCB 0.6V
2.3–2.7
3.0–3.6
750
PA
Increase in ICC per Input, An
VI VCCA 0.6V
2.3–2.7
3.0–3.6
750
PA