![](http://datasheet.mmic.net.cn/230000/92260_datasheet_15571479/92260_2.png)
Description
The Charleswater Europe Critical
Environment overhead ionisers are
available in two models:
The 92260 is a 61 cm long unit with 2
fans, and the 92261 is a 122 cm long
unit with 4 fans. Both models have the
same features permitting the user to
select the best size for the application.
The C/E series offers many design
improvements over previous overhead
models, most notably, our patented
(U.S. Patent No. 6,137,670) "Emitter
Cassette" ( see figure 1). While other
manufacturers attempt to simplify or
automate the cleaning of the emitter
pins, what remains is one major flaw in
the process - unless the ioniser is
removed to another area, the
contamination ends up on the
workstation and on any product that
happens to be nearby. The C/E series
solves this problem. When the emitters
need to be cleaned, the cassettes are
easily removed from the unit and taken
to another area to be cleaned. This
takes the dirt away from the workstation
and minimizes interruption of the work
process. To eliminate downtime, a
spare set of clean emitter cassettes can
be dropped in. The others can be
cleaned when convenient. This concept
is so unique, that we have a patent on it.
Model
Description
92260
61 cm C/E Ioniser, 220VAC
92261
122 cm C/E Ioniser, 220VAC
92662
Replacement Emitter
Cassette
PPE-5060.E
Page 2 of 6
Unit 17. Millbrook Business Park, Sybron Way Crowborough, East Sussex TN6 3JZ United Kingdom
Phone: 00 44 (0) 1892-665313, Fax: 00 44 (0) 1892-668838 E-mail: info@charleswater.co.uk, Internet: www.charleswater.co.uk
Features
Removable emitter cassettes allow
you to minimize contamination of
the work area.
Closed-loop feedback electronic
balance system continuously
monitors output for best
performance.
Lockout key with distinctive front
panel indicator prevents
unauthorized adjustment.
Balance individually adjustable at
each fan zone.
Flashing front panel signal
indicates when cleaning is needed.
IEC input and output connectors
allow daisy-chaining of up to 10
units.
Stainless steel and powder-coated
aluminum construction for
durability.
Specifications
Input Power:
220VAC 250mA (61cm model)
220VAC 400mA (122cm model)
IEC Outlet:
Allows up to 10 units to be daisy-
chained
Fuse:
5 x 20mm 3 amp time lag
Air Flow:
38-80 l/sec (61cm model)
76-160 l/sec (122cm model)
Emitters:
100% Tungsten, replaceable
Ionization Type:
Steady-state DC
Balance:
0+/-10 volts at set-up at 61cm
above charged plate
Weight:
3 kg (61cm model)
5 kg (122cm model)
Size:
5cm x 15cm x 61cm
5cm x 15cm x 122cm
Mounting:
(2) 6mm mounting holes each
end
Installation
The Charleswater Europe C/E ioniser is
designed to mount above the work
area, providing even coverage without
using valuable work surface area.
Mounting is a matter of personal
preference, and may be accomplished
with brackets attached to a shelf, or the
unit may be suspended by chain.
Whatever method is used, care should
be taken to insure that the mounting is
secure and capable of supporting the
weight of the unit. The power cord
should be supported as well to provide
protection against any hazard to the
operator.
"S" hooks are provided with each unit to
facilitate mounting using the chain
suspension method. The ideal
mounting height is 122cm above the
work surface, although the ioniser may
be located slightly higher or lower if
required. Care should be taken to
insure that the intake grills for the fans
are not obstructed for maximum
performance.
Turn the power key switch to the "OFF"
position. Plug the IEC end of the cord
into the ioniser and the other end into a
properly wired outlet. We recommend
that the outlet used by the ioniser be
tested before use and periodically
checked for correct wiring and a good
solid ground. The C/E ioniser depends
on a good ground for proper balancing.
Safety interlock switches are
provided internally on each emitter
cassette. This insures that power is
cut off in the event that any cassette
is removed or not fully installed.
Figure 1. Removable emitter cassette
IMPORTANT: These units are
designed to work with the live and
neutral connections on the mains
plug, being the correct polarity.
On some European plug sockets
the polarity can be either way
round. Before plugging in your
Ioniser, please check the polarity
of your mains socket, and ensure
that the live and neutral match the
live and neutral pins on the mains
socket.
We cannot accept liability for
Ionisers where the unit has been
plugged into the mains socket,
with the polarity reversed.
Please note that these units do
require a properly grounded wall
socket to function correctly.