TIMING SPECIFICATIONS
Table 2. (AVDD = 5 V ± 5%; DVDD = 2.7 V to 3.6 V, or 5 V ± 5%; Input Logic 0 = 0 V; Logic 1 = DVDD; unless otherwise noted.)1 Parameter
Min
Typ
Max
Unit
Test Conditions/Comments
Master Clock Range
1
6.144
MHz
t
1
50
ns
SYNC Pulsewidth
t
2
500
ns
RESET Pulsewidth
Read Operation
t
4
0
ns
CS Falling Edge to SCLK Falling Edge Setup Time
t
5
SCLK Falling Edge to Data Valid Delay
0
60
ns
DV
DD of 4.75 V to 5.25 V
0
80
ns
DV
DD of 2.7 V to 3.3 V
t
CS Falling Edge to Data Valid Delay
0
60
ns
DV
DD of 4.75 V to 5.25 V
0
80
ns
DV
DD of 2.7 V to 3.3 V
t
6
50
ns
SCLK High Pulsewidth
t
7
50
ns
SCLK Low Pulsewidth
t
8
0
ns
CS Rising Edge after SCLK Rising Edge Hold Time
t
9
10
80
ns
Bus Relinquish Time after SCLK Rising Edge
Write Operation
t
11
0
ns
CS Falling Edge to SCLK Falling Edge Setup
t
12
30
ns
Data Valid to SCLK Rising Edge Setup Time
t
13
25
ns
Data Valid after SCLK Rising Edge Hold Time
t
14
50
ns
SCLK High Pulsewidth
t
15
50
ns
SCLK Low Pulsewidth
t
16
0
ns
CS Rising Edge after SCLK Rising Edge Hold Time
1 Sample tested during initial release to ensure compliance. All input signals are specified with tr = tf = 5 ns (10% to 90% of DV
DD) and timed from a voltage level of
2 These numbers are measured with the load circuit of Figure 4 and defined as the time required for the output to cross the V OL or VOH limits.
3 This specification is relevant only if CS goes low while SCLK is low.
4 These numbers are derived from the measured time taken by the data output to change 0.5 V when loaded with the circuit of Figure 4. The measured number is then extrapolated back to remove effects of charging or discharging the 50 pF capacitor. This means that the times quoted in the Timing Characteristics are the true bus