ADG858
Rev. A | Page 5 of 16
ABSOLUTE MAXIMUM RATINGS
TA = 25°C, unless otherwise noted.
Table 3.
Parameter
Rating
VDD to GND
0.3 V to +6 V
0.3 V to VDD + 0.3 V
0.3 V to VDD or 10 mA,
whichever occurs first
Peak Current, S or D
500 mA (pulsed at 1 ms,
10% duty cycle max)
Continuous Current, S or D
250 mA
Operating Temperature Range
40°C to +85°C
Storage Temperature Range
65°C to +150°C
Junction Temperature
150°C
16-Lead Mini LFCSP
θJA Thermal Impedance, 3-Layer Board
84.9°C/W
Reflow Soldering, Pb-Free
Peak Temperature
260(+0/5)°C
Time at Peak Temperature
10 sec to 40 sec
1 Overvoltages at IN, S, or D are clamped by internal diodes. Current should be
limited to the maximum ratings given.
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
Only one absolute maximum rating can be applied at any one time.
ESD CAUTION