ABSOLUTE MAXIMUM RATINGS
Storage Temperature . . . . . . . . . . . . –65
°
C to +125
°
C
Ambient Temperature
with Power Applied. . . . . . . . . . . . . . –55
°
C to +125
°
C
Voltage with Respect to Ground
All pins except A9 and V
PP
(Note 1) .–2.0 V to +7.0 V
V
CC
(Note 1). . . . . . . . . . . . . . . . . . . .–2.0 V to +7.0 V
A9, V
PP
(Note 2) . . . . . . . . . . . . . . .–2.0 V to +14.0 V
Output Short Circuit Current (Note 3) . . . . . . 200 mA
Notes:
1. Minimum DC voltage on input or I/O pins is –0.5 V During
voltage transitions, input or I/O pins may overshoot V
SS
to
–2.0 V for periods of up to 20 ns. Maximum DC voltage on
input or I/O pins is V
CC
+0.5 V During voltage transitions,
input or I/O pins may overshoot to V
CC
+2.0 V for periods
up to 20 ns.
2. Minimum DC input voltage on pins A9 and V
PP
is –0.5 V
During voltage transitions, A9 and V
PP
may overshoot
V
SS
to –2.0 V for periods of up to 20 ns. Maximum DC
input voltage on pin A9 and V
PP
is +13.0 V which may
overshoot to 14.0 V for periods up to 20 ns.
3. No more than one output may be shorted to ground at a
time. Duration of the short circuit should not be greater
than one second.
4. Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device. This
is a stress rating only; functional operation of the device at
these or any other conditions above those indicated in the
operational sections of this data sheet is not implied.
Exposure of the device to absolute maximum rating
conditions for extended periods may affect device reliability.
OPERATING RANGES
Commercial (C) Devices
Ambient Temperature (T
A
). . . . . . . . . . . .0°C to +70°C
Industrial (I) Devices
Ambient Temperature (T
A
). . . . . . . . . .–40°C to +85°C
Extended (E) Devices
Ambient Temperature (T
A
). . . . . . . . .–55°C to +125°C
V
CC
Supply Voltages
V
CC
. . . . . . . . . . . . . . . . . . . . . . . +4.50 V to +5.50 V
V
PP
Voltages
Read . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to +12.6 V
Program, Erase, and Verify. . . . . . +11.4 V to +12.6 V
Operating ranges define those limits between which the
functionality of the device is guaranteed.